Part Number 040005626 5/17 105REFRIGERANT RE-USE POLICYManitowoc recognizes and supports the need forproper handling, re-use, and disposal of refrigerants.Manitowoc service procedures require recapturingrefrigerants, not venting them to the atmosphere.It is not necessary, in or out of warranty, to reduce orcompromise the quality and reliability of yourcustomers’ products to achieve this.Manitowoc approves the use of:1. New Refrigerant• Must be of original nameplate type.2. Reclaimed Refrigerant• Must be of original nameplate type.• Must meet ARI Standard 700 (latest edition)specifications.3. Recovered or Recycled Refrigerant• Must be recovered or recycled in accordancewith current local, state and federal laws.• Must be recovered from and re-used in thesame Manitowoc product. Re-use of recoveredor recycled refrigerant from other products isnot approved.• Recycling equipment must be certified to ARIStandard 740 (latest edition) and bemaintained to consistently meet this standard.ImportantManitowoc assumes no responsibility for use ofcontaminated refrigerant. Damage resultingfrom the use of contaminated, recovered, orrecycled refrigerant is the sole responsibility ofthe servicing company.