Table 3. Events organized by severity (continued)Event ID Message String SeverityFQXSFMA0033M Intel Optane DCPMM persistent memory interleave set has [arg1]DCPMMs(DIMM [arg2]), [arg3] DIMMs' location is not correct.WarningFQXSFMA0034M DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memoryinterleave set should be moved to DIMM slot [arg3] in sequence.WarningFQXSFMA0035M Intel Optane DCPMM interleave set should have [arg1] DCPMMs, but[arg2] DCPMMs are missing.WarningFQXSFMA0036M DIMM [arg1] (UID: [arg2]) of Intel Optane DCPMM persistent memoryinterleave set is missing.WarningFQXSFMA0037G Intel Optane DCPMM interleave set (DIMM [arg1]) is migrated fromanother system (Platform ID: [arg2]), these migrated DCPMMs are notsupported nor warranted in this system.WarningFQXSFMA0038K All Intel Optane DCPMMs could not be auto unlocked because of nopassphrase.WarningFQXSFMA0039K One or more Intel Optane DCPMMs could not be auto unlockedbecause of invalid passphrase.WarningFQXSFMA0040K Invalid Intel Optane DCPMM configuration detected. Please verifyDCPMM configuration is valid.WarningFQXSFMA0041K Near Memory/Far Memory ratio (1:[arg1].[arg2]) for Intel OptaneDCPMM configuration is not in recommended range (1:2 - 1:16).WarningFQXSFMA0047M SPD CRC checking failed on DIMM [arg1]. [arg2] WarningFQXSFPU0021G Hardware physical presence is in asserted state. WarningFQXSFPU0022G The TPM configuration is not locked. WarningFQXSFPU0023G Secure Boot Image Verification Failure Warning. WarningFQXSFPU0033G Processor has been disabled. WarningFQXSFPU0062F System uncorrected recoverable error happened in Processor [arg1]Core [arg2] MC bank [arg3] with MC Status [arg4], MC Address [arg5],and MC Misc [arg6].WarningFQXSFPU4033F TPM Firmware recovery is in progress. Please DO NOT power off orreset system.WarningFQXSFPU4035M TPM Firmware recovery failed. TPM chip may be damaged. WarningFQXSFPU4040M TPM selftest has failed. WarningFQXSFPU4043G TPM Firmware update aborted. System is rebooting... WarningFQXSFPU4045G Physical Presence is not asserted, abort TPM Firmware upgrade. WarningFQXSFPU4050G Failed to update TPM Firmware. WarningFQXSFPU4051G Undefined TPM_TCM_POLICY found WarningFQXSFPU4052G TPM_TCM_POLICY is not locked WarningFQXSFPU4053G System TPM_TCM_POLICY does not match the planar. WarningFQXSFPU4054G TPM/TCM card logical binding has failed. WarningFQXSFPW0001L CMOS has been cleared. Warning156 ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 ComputeNode Messages and Codes Reference