User Action:Information only; no action is required• FQXSPPW0009I: [PowerSupplyElementName] has been Power Cycled.This message is for the use case when an implementation has detected a Power Unit that has been powercycled.Severity: InfoServiceable: NoAutomatically notify Support: NoAlert Category: System - OtherSNMP Trap ID:CIM Prefix: PLAT CIM ID: 0108User Action:Information only; no action is required• FQXSPPW0031J: Numeric sensor [NumericSensorElementName] going low (lower non-critical) hasasserted.This message is for the use case when an implementation has detected a Lower Non-critical sensor goinglow has asserted.Severity: WarningServiceable: YesAutomatically notify Support: NoAlert Category: Warning - VoltageSNMP Trap ID: 13CIM Prefix: PLAT CIM ID: 0476User Action:CMOS battery is recommended to replace with new one.• FQXSPPW0035M: Numeric sensor [NumericSensorElementName] going low (lower critical) hasasserted.This message is for the use case when an implementation has detected a Lower Critical sensor going lowhas asserted.Severity: ErrorServiceable: YesAutomatically notify Support: YesAlert Category: Critical - VoltageSNMP Trap ID: 1CIM Prefix: PLAT CIM ID: 0480User Action:Use one of the following procedures:1. If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only)replace the system board.2. If the specified sensor is Planar 12V, check the System Management Module or xClarify Controllerevent log for power-supply-related issues, and resolve those issues.3. If the problem remains, replace (trained technician only)the system board.• FQXSPPW0047M: Numeric sensor [NumericSensorElementName] going high (upper critical) hasasserted.Chapter 3. XClarity Controller events 113