Diagnostic Error Code FRU/Action001-038-XXX System Extension failure 1. Adapter card2. System board001-039-XXX System DMI data structure error 1. Flash the system. See “Flash update procedures”on page 2592. System board001-040-XXX System IRQ failure 1. Power-off/on system and re-test2. System board001-041-XXX System DMA failure 1. Power-off/on system and re-test2. System board001-195-XXX System Test aborted by user Information only Re-start the test, if necessary001-196-XXX System test halt, error threshold exceeded 1. Press F3 to review the log file2. Re-start the test to reset the log file001-197-XXX System test warning 1. Make sure the component that is called out isconnected and/or enabled. See Chapter 6 “Usingthe Setup Utility” on page 392. Re-run test3. Replace the component that is called out in warningstatement4. Replace the component under test001-198-XXX System test aborted 1. If a component is called out, make sure it isconnected and/or enabled. See Chapter 6 “Usingthe Setup Utility” on page 392. Flash the system and retest. See “Flash updateprocedures” on page 2593. Go to “Undetermined problems” on page 73001-199-XXX System test failed, cause unknown 1. Go to “Undetermined problems” on page 732. Flash the system and re-test3. Replace component under function test001-250-XXX System ECC error System board001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXXSystem DMA errorSystem board001-260-XXX 001-264-XXX System IRQ error System board001-268-XXX System IRQ1 failure 1. Device on IRQ12. System board001-269-XXX System IRQ2 failure 1. Device on IRQ22. System board001-270-XXX System IRQ3 failure 1. Device on IRQ32. System board001-271-XXX System IRQ4 failure 1. Device on IRQ42. System board001-272-XXX System IRQ5 failure 1. Device on IRQ52. System board54 ThinkStation Hardware Maintenance Manual