Page Operating Instructions blueplanet 1502xi/2502xi. Level 1 menu – Display modeThe display menu is shown once the blueplanet inverter startsup. Measured values and all of the counters are displayedhere. Key “1” is used to navigate through the individual menuitems.Display of inverter typeGenerator voltage and currentGrid voltage, current and powerDaily peak capacityTemperature inside unitCounter yieldYield todayTotal yield(Total) economy of CO2Counter oper. hoursOperating hours todayTotal operating hoursFigure 4.4: Display mode menuExplanation of the individual menu items:Inverter type displayInverter type blueplanet 1502xi/2502xi displayGenerator voltage and currentThe current voltage and current of the PV solar generator thatis connected to the inverter.Grid voltage, current and powerThe current line voltage, line current, and the power that iscurrently being fed into the power grid.Daily peak capacityThe respective day’s peak power that was fed into the grid fora short time.Temperature inside unitDisplays the current heat sink temperature. If the unit becomestoo hot, the unit will reduct power output or switch off.Counter yieldThis counter totals all yields until it is reset. The customer canconfigure the time periods for this counter, e.g. as a monthlycounter. The counter can be cleared in configuration mode“Clear yield”.Yield todayThe power that has been fed into the grid during the currentday. This value resets to zero each morning.Total yieldThe power that has been fed into the grid since installationof the inverter. The initial value can be set in configurationmode.(Total) economy of CO2Shows the CO2 savings of this PV installation compared to theGerman electricity mix. The CO2 savings are calculated from thetotal yield counter and can also be cleared with this counter.Counter oper. hoursThis counter totals all yields until it is reset again. The cus-tomer can configure the time periods for this counter, e.g. asa monthly counter. It can be cleared in configuration mode“Clear yield”.Operating hours todayToday’s hours of operation. As soon as the inverter is in stand-by mode (i.e. when LED (1) lights up), the running time is addedup.Total operating hoursThe hours of operation since installation of the inverter. Assoon as the inverter is in stand-by mode (i.e. when LED (1)lights up), the running time is added up.Section · Operation