Post-Installation Configuration & CheckoutApollo CNX80 Installation Manual 560-0982-00 Rev D 3-13 POST I NSTALLATION CONFIGURATION & CHECKOUTPROCEDURESOnce the CNX80 unit has been installed, configure the unit for the particular installation and then completethe checkout procedures herein to verify proper operation. The steps that are not applicable to a particularinstallation may be skipped. A checkout log sheet is included in Table 3-5 on page 3-32, to be filled outduring the checkout procedure. The completed checkout log sheet should be maintained with the aircraftpermanent records.3.1 M OUNTING AND W IRING CHECKVerify that all cables are properly secured and shields are connected as the install drawings indicate.Installation may require that you check the movement of the aircraft controls to verify that there is nointerference.3.2 E QUIPMENT S ETUP AND CONFIGURATIONPrior to system operation, the CNX80 must be configured for the particular installation using the setupfunctions provided.The system setup and checkout functions are reached in the Ground Maintenance mode of the CNX80.This mode should not be accessed during flight. The Ground Maintenance mode is reached by pressing theline select keys 1, 4, and MENU/ENTER in sequence immediately after the CNX80 initialization iscomplete and before any other bezel keys on the CNX80 are pressed. Line select key 1 is the top line selectkey, line select key 4 is the fourth key down, and MENU/ENTER is the lower most key below the lineselect keys. After pressing the keys, wait for the CNX80 to restart into Ground Maintenance mode. TheGround Maintenance mode default menu display (SETUP) is shown in Figure 3-1. Pressing the SETUP,TEST or INPUT smart keys along the bottom allows selection of that function. Pressing the EXIT smartkey will return the CNX80 to the Airborne mode.Figure 3-1 - Ground Maintenance Mode Display