Vers. No. 4.060 Released: 5/12/20114 Connecting the modules → Q.bloxx A107: Connecting sensors4.13 Q.bloxx A107: Connecting sensorsThe Q.bloxx Module A 107 has four electrically isolated analoginputs. The pin assignment of the two connector strips is identicaland the connection terminals have numbers for identifying theconnections. If several connections are possible, you will find theassociated ones in each case at the same place in the circuit dia-grams, for example the figures quoted in the second place belongin each case to one possible connection method.GND identifies the measurement ground. The four inputs (UF toGND) are electrically isolated in the module one to the other andto the (module) supply voltage.Fig. 4-48 Pin assignment for Q.bloxx Module A107.TipFurther information on transducers and sensors can also befound in Chapter 6 from Page 107 onwards.4.13.1 VoltageYou can measure voltages of up to 10 V.4, 93, 81, 6 (+)5, 10 (GND)U2, 7 (+)5, 10 (GND)I2, 7 (+)5, 10 (GND)1, 6 (+)5, 10 (GND)2, 71, 62, 71, 64, 92, 73, 83, 7 (–)2, 6 (+)1 UF2 A In 13 A In 24 A In 35 GND6 UF7 A In 18 A In 29 A In 310 GND1 UF2 AIn 13 A In 24 A In 35 GND6 UF7 A In 18 A In 29 A In 310 GND10110 1Plug 1Plug 2requires Q.bloxxTerminal CJC