OneStart
Menu
Home
Features
Browser
Content
Partner
Coupons
Manuals
Blog
Download
Search
Manuals database
Brands
Gantner
Measuring Instruments
Q Series
Gantner Q Series Manual
Gantner Q Series Manual
Also see for Q Series:
Manual
Manual
Manual
Manual
Manual
Table of content
Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Table Of Contents
Safety Information
Special risks
Disposal
Labels and warning information
Labels in this manual
Introduction
The documentation in the Q.bloxx range
System description
Operating the modules via Q.pac
Operating the modules without Test Controller
Connecting the modules
Hot swap (factory setting)
Setting the address (optional)
Activating the terminating resistances
Mounting/removing bases
Q.bloxx Extension Socket QES
Connecting the power supply
Fitting and removal of modules from bases
Connecting interfaces
Connecting modules to Q.pac
Connecting Q.gate/Q.pac via Ethernet to a PC/PLC
Using the RS-232 interface of Q.gate or Q.pac
Connecting modules directly to a PC/PLC
Synchronization of several systems
Connection of a radio receiver for time signals
Module flashing frequency
Problems during data transmission
The modules and their connection options
Q.bloxx A101: Connecting sensors and I/O
Current
Thermocouple
Strain-gauge quarter bridges
Digital input and output
Q.bloxx A102: Connecting sensors and I/O
Q.bloxx A103: Connecting sensors and I/O
Q.bloxx A104: Connecting sensors
Q.bloxx A105: Connecting sensors
Q.bloxx A106: Connecting sensors and I/O
Strain-gauge quarter bridge
LVDT, RVDT
Q.bloxx A107: Connecting sensors
Strain-gauge half and quarter bridges
Q.bloxx A108: Connecting sensors and I/O
Q.bloxx A109: Connecting I/O and outputs
Analog output, Plug 2
Q.bloxx A111: Connecting sensors and I/O
IEPE/ICP ® Sensor
Q.bloxx A116: Connecting sensors
Full and half-bridge transducers
Activating the shunt resistance
Q.bloxx A123: Connecting sensors
Voltage
Q.bloxx A124: Connecting sensors
Q.bloxx A127: Connecting sensors
Q.bloxx A128: Connecting sensors
Q.bloxx D101: Connecting I/O
Q.bloxx D104: connecting digital inputs
Q.bloxx D105: connecting digital outputs
Q.bloxx D107: Connecting digital inputs
Configuration
Installing the test.commander
Using test.commander
test.commander and the serial (service) interface
Creating a project for configuration
Configuring analog inputs
Carrier frequency synchronization (Q.bloxx A106)
Zero balancing/taring the sensor
Sensor scaling over several points (table)
Specifying digital inputs/outputs
Configuring analog outputs
Defining computations
Specifying the alarm monitoring
Q.gate and Q.pac settings
Host interface
Storage settings (only Q.pac)
Virtual variable
Online tools
Reading module information
Reading status information
Firmware update
Firmware update for modules
Functional Procedures
Bus termination on the Q.bloxx modules
Network topologies
Ethernet on the PC
Setting the IP address on the PC
Allowing access to network devices (firewall)
Connecting sensors with sensing leads
Sensor scaling
Scaling strain gauges
Current measurement with an external shunt
Measuring with thermocouples
International Sales and Service
Manual
Q.bloxx
Vers. No. 6.1
Next
/ 150
Related manuals for Gantner Q Series
Gantner e.bloxx D1 Series Instruction Manual
Gantner Q.brixx Quick Start Manual
This manual is suitable for:
Q Series
Q.bloxx A101
Q.bloxx A102
Q.bloxx A103
Q.bloxx A104
Q.bloxx A106
Q.bloxx A107
Q.bloxx A108
Q.bloxx A109
Q.bloxx A123
Q.bloxx A124
Q.bloxx D101
Q.bloxx D104
Q.bloxx D105
Q.bloxx A105
Q.bloxx A111
Q.bloxx A116
Q.bloxx A127
Q.bloxx A128
Q.bloxx D107