Vers. No. 6.144 Released: 25/04/20174 Connecting the modules → The modules and their connection options4.7 The modules and their connection options1) Half bridge only with Q.bloxx Terminal2) Quarter bridge with Q.bloxx TerminalModules: A101A102A103A104A105A106A107A108A109A111A116Signal inputsVoltage X X X X X X XCurrent X X X X XPotentiometer X XResistance X X XPt100, Pt1000 X X XThermocouple X X X(Strain gauges) full + halfbridge X X X X1) XStrain-gauge quarter bridge X 2) X 2) X 2) X2) XInductive full and half bridge XLVDT, RVDT XIEPE/ICP® Sensor X X XDigital input: frequency,pulse width, counter XDigital input: Status X X X X X XSignal outputsVoltage X X XCurrent X XDigital output: frequency, pulse width XDigital output: Status X X X X X XNumber of channels 2 1 8 8 4 2 4 8 4 4 8Data rate (in Hz) 100 k 100 k 100 100 10 10 k 10 k 10 k 100 k 100 k 10 kFor description refer to page 46 51 55 57 59 61 65 69 71 73 75