When checking the connection between the PC terminal and the ETERNUS DX, execute the "ping" com-mand at the PC command prompt. An example of ping execution is shown below. ("192.168.1.1" is thedefault IP address for the ETERNUS DX)ping 192.168.1.1If the execution results in an error, check the network settings of the PC terminal.When communication cannot be secured even after the RMT port of Controller 0 (CM#0) is connectedto the LAN port of the PC terminal, make sure that the MASTER LED of Controller 0 (CM#0) is turnedon. When the MASTER LED of Controller 1 (CM#1) is turned on, use the RMT port of Controller 1(CM#1).5.3 ETERNUS Web GUI StartupStart up ETERNUS Web GUI via the Web browser of the connected terminal.If the settings of the Web browser are incorrect, ETERNUS Web GUI may not be connected. For details onthese settings, refer to "Configuration Guide (Web GUI)".1 Open the Web browser on the terminal.2 Enter the following URL in the address bar of the Web browser:http://192.168.1.1/The login screen for ETERNUS Web GUI appears.3 To change the language, click the [Option] button and select [English] or [Japanese] in [Language].4 Enter the User ID and Password.User ID: rootPassword: root (by default)Chapter 5 General Settings5.3 ETERNUS Web GUI Startup39FUJITSU Storage ETERNUS DX200F All Flash Array Configuration Guide (Basic)Copyright 2014 FUJITSU LIMITEDP3AM-8462-01ENZ0