CHAPTER 6 FIXING SYSTEMCOPYRIGHT © 1999 CANON INC. CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON) 6-3B. Operation of Fixing Assembly Temperature Control SystemFigure 6-102Note:When the preheat mode starts in response to a press on the STANDBY key, the fixing tem-perature is controlled to 155°C.Power switch ONWARM-UP50˚C 110˚C COPY START key ONCOPY START key indicatorFixing roller heater (H1)Exhaust fan (FM2)195˚C180˚C155˚C110˚C50˚C0˚CMain motor (M1)Scanner cooling fan (FM1)WARM-UPROTATION STAND-BY SCANNERFORWARD SCANNERREVERSEBlinks green Glows green Glows redSCANNERFORWARD SCANNERREVERSE LASTROTATIONGlows greenSTAND-BY