8. Routing the Lens X Direction Drive BeltFix the lens X direction drive motor q with the mounting screw w where the motorhas lowered on its own weight.Figure 11-2169. Adjusting the Position of the Scanner Locking Solenoid (SL1)1) Remove the rear cover.2) Remove the multifeeder assembly. (See Chapter 5.)3) Adjust the stroke of the scanner locking solenoid as indicated.Figure 11-217E-ringStandards(10.5 ±0.5 mm;from bottom ofclamp to top ofsolenoid)Scanner lockingsolenoidLoosen thesetwo screws toadjust.qwOwn weightCOPYRIGHT © 1997 CANON INC. CANON NP6350/NP6251 REV. 0 JULY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)CHAPTER 11 TROUBLESHOOTING11-16Download service manual and resetter printer at http://printer1.blogspot.com