CHAPTER 3 MECHANICAL SYSTEMSCOPYRIGHT © 2001 CANON INC. 2000 2000 2000 2000 CANON DADF-H1 REV.0 MAR. 20013-163.2.2 Removing the feed stationWhen detaching the feed mechanism com-ponents (separation roller, registrationroller, lower, read roller, read roller, platenroller, delivery reversal roller, etc.), releasethe feed station as a whole by followingthese steps:1) Detach the front cover, rear cover, andfeeder cover.2) Disassemble the drive mechanism.3) Remove two screws [1] from the frontcover to release locking support [2] andconnector [3].F03gv-302-034) Remove screw [4] to pull out bushing[5] and then release document pickuptray [6].F03-302-04[1] [3][2][6][4] [5]