2010 Portable SpaLTR20101001, Rev. BOperating Your Spawww.calspas.com15When first powered up, the electronicsystem will perform a self-diagnostic checkand then it will automatically heat to andmaintain a temperature of 37.5˚C until youchange the set temperature as listed in the“Temperature Adjustment” section below.These instructions will describe featuresand options that your particular spa maynot be equipped with.Initial Start-upWhen your spa is first powered up, itdisplays some configuration codes andthen goes into priming mode (Pr will appear on thedisplay panel). This mode lasts up to four minutes andthen the spa begins to heat to its pre -programmedtemperature of 37.5˚C. You can exit the priming modeearly by pressing UP or DOWN buttons.Temperature Adjustment (26.0˚C -40.0˚C)The start-up temperature is set at 37.5˚C. The lastmeasured temperature is constantly displayed onthe control panel. Note that the last measured spatemperature is displayed. The displayed temperaturewill be updated when the pump has been running forat least two minutes.Press the UP or DOWN buttons once to display theset temperature. Each time either button is pressedagain, the set temperature will increase or decreasedepending on which button is pressed. After threeseconds, the control panel will automatically displaythe last measured spa temperature.TimeWhen time hasn’t been programmed, the TIME iconflashes. To set the time, press the TIME button andthen the MODE/PROG button. Use the UP and DOWNbuttons to adjust time. See the next page for moredetailed instructions.Standard, Economy, Sleep, andStandby ModesMode/Prog: This button is used to switch betweenstandard, economy, and sleep modes.Press MODE/PROG to enter mode programming.1.Press the DOWN button to cycle through to the2.desired mode.8005 and 9005 Electronic Control OperationPress MODE/PROG to confirm selection.3.Standard Mode: This is programmed to maintainthe desired temperature. Note that the last measuredspa temperature displayed is current only when thepump has been running for at least two minutes. The“STAND” icon will display until the mode is changed.Economy Mode: Economy mode heats the spa to theset temperature only during filter cycles. The “ECON”icon will display until the mode is changed. Pressingthe JETS 1 button while in economy mode puts thespa in standard-in-economy mode, which operates thesame as standard mode but reverts back to economymode automatically after one hour. During thistime, pressing the MODE/PROG button will revert toeconomy mode immediately.Sleep Mode: Sleep mode heats the spa to within 11˚Cof the set temperature only during filter cycles. The“SLEEP” icon will display until the mode is changed.Standby Mode: Pressing “Warm” or “Cool” then“Jets 2” will turn off all spa functions temporarily. Thisis helpful when changing a filter. Pressing any buttonresets the spa.Jets 1 and Jets 2Press the JETS 1 button once to turn pump 1 on or offand to shift between low and high speeds if equipped.If left running, the low speed turns off after two hoursand the high speed turns off after 15 minutes. Onnon-circulation systems, the low speed of pump 1runs when the blower or any other pump is on. It mayalso activate for at least two minutes every 30 minutesto detect the spa temperature and then to heat tothe set temperature if needed, depending upon themode. When the low speed turns on automatically, itcannot be deactivated from the panel; however, thehigh speed may be started.