Absolute Process Instruments Cecomp F16DR Series Instructions Manual
Cecomp® Programmable 4-Wire Digital Pressure Transmitters F16DR, F16DRNRanges and ResolutionSee table below. Consult factory for special engineering units.Resolution is fixed as indicated in table.F16DRO ±0.25% Test Gauge AccuracyO 316L Stainless Steel Wetted PartsO Low Voltage PoweredO 4-20 mA or 0-2 V Analog OutputO Output Test FunctionAccuracyAccuracy includes linearity, hysteresis, repeatabilityStandard accuracy: ±0.25% of full scale ±1 least significant digitHA accuracy option: ±0.1% FS ±1 LSD, see ranges for availabilitySensor hysteresis: ±0.015% FS, included in accuracySensor repeatability: ±0.01% FS, included in accuracyDisplay4 readings per second nominal display update rate4 digit LCD, 0.5" H and 5 character 0.25" H alphanumericDRBL: Red LED backlight on when gauge is onControlsSEL Select display for setupTEST Set output to test level when in test modes Up: Increase when in test or calibration modet Down: Decrease when in test or calibration modeZero/tare function can be enabled or disabledCalibrationUser settable pass code required to enter calibration modeAll pressure and absolute models: zero, midpoint, spanAll vacuum models: –span, –midpoint, zeroVacuum/pressure models: –span, zero, +midpoint, +span±15 psi models: –span, –midpoint, zero, +midpoint, +spanOutput CharacteristicsUpdated approximately 16 times per secondUser scalable pressure range to correspond to output-I: Current output, 4-20 mA DCOutput drive (compliance) determined by power source6,553 counts over sensor range-V: Voltage output, 0-2 VDC into 5k ohm or greater6,553 counts over sensor range-BV: Bipolar voltage output (–2 - 0 - 2 V) for ±15 psig sensor only±2 VDC into 5k ohm or greater13,107 counts over sensor rangePower8-24 VAC 50/60 Hz or 9-32 VDCGauge is on when power is on. Designed for continuous operation.DR: 30 mA maximumDRBL: Approximately 40 mA maximumWeight9.5 ounces (approx.), shipping wt. 1 pound (approx.)HousingF16DR: Extruded aluminum case, epoxy powder coated, ABS/polycarbonate bezel (aluminum bezel optional), front and reargaskets, polycarbonate labelF16DRN: ABS/polycarb. NEMA 4X case, rear gasket, polycarb. labelConnection, Material, Media Compatibility1/4" NPT male fitting. All wetted parts are 316L stainless steel.Overpressure, Burst, VacuumRanges using 3000 psig sensor: 5000 psigRanges using 5000 psig sensor: 7500 psigAll others: 2 X pressure range3000 psi, 5000 psi, and 4 digit ranges 112.5% full scale out-of-range display: 1– – – or I –.–.–.–4 X sensor burst pressure rating, or 10,000 psi, whichever is lessVacuum service: 15 psia, ±15 psig, 15 psig, 30 psia,100 psig, 100 psia, 200 psig sensorsUnder-range display (non-vacuum sensors): –ErrEnvironmentalStorage temperature: –40 to 203°F (–40 to 95°C)Operating temperature: –4 to 185°F (–20 to 85°C)Compensated temperature: 32 to 158°F (0 to 70°C)How to Specify TypeF16DR range - output - options Standard housingF16DRBL range - output - options Standard housing,backlit displayF16DRN range - output - options NEMA 4X housingF16DRNBL range - output - options NEMA 4X housing,backlit display1.65"2.88"3 ft long,4-conductor22 AWGshieldedcable NEMA 4X3.0"2.0"Turn at hexfittingonly!Turn at hexfittingonly!3 ft long,4-conductor22 AWGshieldedcableG = gauge reference pressureVAC = gauge reference vacuumA = absolute referenceOutputSpecify: I 4-20 mAV 0-2 VBV ±2 V for ranges using ±15 psig sensor onlypsi = PSIinHg = INHGoz/in2 = ZINinH2O = INH2OftH2O = FTH2OmmHg = MMHGtorr = TORRmmH2O = MMH2Okg/cm2 = KGCMg/cm2 = GCMkPa = KPAMPa = MPAmbar = MBARbar = BARcmH2O = CMH2Oatm = ATMRange—see table at leftF16DRN¼" NPT 0.75"SEL TEST tsX X X X X888882Cecomp Electronics / Made in USA3.38" Standard3.5" NEMA 4XH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USA‡ -HA option not availablePSI Res inHg/PSI Res mmH2O Res3PSIG‡ .001 –30V15PSIG‡ .1 2100MMH2OG‡ 15PSIG‡ .001 –30V100PSIG‡ .1 3500MMH2OG‡ 115PSIA .01 –30V200PSIG‡ .1 cmH2O Res15PSIVAC‡ .01 inH2O Res 210CMH2OG‡ .1±15PSIG‡ .01 85INH2OG‡ .01 350CMH2OG‡ .115PSIG .01 140INH2OG‡ .1 1000CMH2OA 130PSIA .01 400INH2OA .1 1000CMH2OVAC‡ 130PSIG .01 400INH2OVAC‡ .1 ±1000CMH2OG‡ 160PSIG .01 ±400INH2OG‡ 1 1000CMH2OG 1100PSIA .1 400INH2OG .1 2100CMH2OA 1–15V100PSIG‡ .1 850INH2OA 1 2100CMH2OG 1100PSIG .1 850INH2OG 1 kPa Res–15V200PSIG‡ .1 ftH2O Res 20KPAG‡ .01200PSIG .1 7FTH2O‡ .001 35KPAG‡ .1300PSIG .1 12FTH2O‡ .01 100KPAA .1500PSIG .1 35FTH2O .1 100KPAVAC‡ .11000PSIG 1 70FTH2O .1 ±100KPAG‡ .12000PSIG 1 140FTH2O .1 100KPAG .13000PSIG 1 230FTH2O .1 200KPAA .15000PSIG 1 480FTH2O .1 200KPAG .1oz/in2 Res 700FTH2O .1 400KPAG .150ZING‡ .01 1150FTH2O 1 700KPAA .180ZING‡ .1 2300FTH2O 1 700KPAG .1240ZINA .1 4600FTH2O 1 –100V700KPAG‡ 1240ZINVAC‡ .1 6900FTH2O 1 1400KPAG 1±240ZING‡ .1 mmHg Res –100V1400KPAG‡ 1240ZING .1 150MMHGG‡ .1 2000KPAG 1480ZINA .1 260MMHGG‡ .1 3500KPAG 1480ZING .1 760MMHGA .1 7000KPAG 1inHg Res 760MMHGVAC‡ .1 MPa Res6INHGG‡ .001 ±760MMHGG‡ 1 1.4MPAG .00110INHGG‡ .01 760MMHGG .1 –0.1V1.4MPAG‡ .00130INHGA .01 1600MMHGA 1 2MPAG .00130INHGVAC‡ .01 1600MMHGG 1 3.5MPAG .001±30INHGG‡ .01 Torr Res 7MPAG .00130INHGG .01 760TORRA .1 14MPAG .0160INHGA .01 760TORRVAC‡ .1 20MPAG .0160INHGG .01 1600TORRA 1 35MPAG .01120INHGG .1 mbar Res g/cm2 Res200INHGA .1 200MBARG‡ .1 200GCMG‡ .1–30V200INHGG‡ .1 350MBARG‡ .1 350GCMG‡ .1200INHGG .1 1000MBARA 1 1000GCMA 1–30V400INHGG‡ .1 1000MBARVAC‡ 1 1000GCMVAC‡ 1400INHGG .1 ±1000MBARG‡ 1 ±1000GCMG‡ 1600INHGG .1 1000MBARG 1 1000GCMG 11000INHGG 1 2000MBARA 1 2100GCMA 12000INHGG 1 2000MBARG 1 2100GCMG 14000INHGG 1 bar Res kg/cm2 Resatm Res 1BARA .001 1KGCMA .0011ATMA .001 1BARVAC‡ .001 1KGCMVAC‡ .0011ATMVAC‡ .001 ±1BARG‡ .001 ±1KGCMG‡ .001±1ATMG‡ .001 1BARG .001 1KGCMG .0011ATMG .001 2BARA .001 2KGCMA .0012ATMA .001 2BARG .001 2KGCMG .0012ATMG .001 4BARG .001 4KGCMG .0014ATMG .001 7BARA .001 7KGCMA .0017ATMA .001 7BARG .001 7KGCMG .0017ATMG .001 –1V7BARG‡ .01 –1V7KGCMG‡ .01–1V7ATMG‡ .01 14BARG .01 14KGCMG .0114ATMG .01 –1V14BARG‡ .01 –1V14KGCMG‡ .01–1V14ATMG‡ .01 20BARG .01 20KGCMG .0120ATMG .01 35BARG .01 35KGCMG .0134ATMG .01 70BARG .01 70KGCMG .0170ATMG .01 140BARG .1 140KGCMG .1140ATMG .1 200BARG .1 200KGCMG .1200ATMG .1 350BARG .1 350KGCMG .1340ATMG .1Quick Link: cecomp.com/xmtrNEMA 4XHousingOptions—add to end of model numberHA High accuracy, ±0.1% FS ±1 LSD. See table at left foravailability.PM Panel mount, 4.1" x 4.1", n/a NEMA 4XCC Moisture resistant circuit board conformal coatingCD Calibration data; 5 test points and dateNC NIST traceability documentation, 5 points and dateAccessories—order separatelyWMPSK Wall mount power supply kit, 115 VAC/12 VDCSCR14SSFilter screen fitting keeps debris out of gaugesensor. Use for food vacuum packaging applica-tions. 303 SS body, 100 micron 304 SS screen.© 08-18cecomp.com1220 American Way Libertyville, IL 60048800-942-0315CECOMP Div. of ABSOLUTE PROCESS INSTRUMENTSAllow 1"clearanceAllow 1"clearance |
Related manuals for Absolute Process Instruments Cecomp F16DR Series
Absolute Process Instruments Cecomp DPG1000DR Series Instructions Manual
Absolute Process Instruments Cecomp F16LSC Instructions Manual
Absolute Process Instruments DuoPak APD 2015 Instructions Manual
Absolute Process Instruments APD 44 Series Quick Start Manual
Absolute Process Instruments APD 44H Series Quick Start Manual
Absolute Process Instruments API 6380 G Series Quick Start Manual
Absolute Process Instruments APD 4300 Manual
Absolute Process Instruments API 6380 G HV Series Quick Start Manual
Absolute Process Instruments API 1600 G Manual
Absolute Process Instruments APD 7580 Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved