OneStart

Honeywell SLC manuals

SLC first page preview

SLC

Brand: Honeywell | Category: Control Panel
Table of contents
  1. installation precautions
  2. Table Of Contents
  3. Table Of Contents
  4. Table Of Contents
  5. Section 1: Introduction
  6. Reference Documentation
  7. Overview
  8. Devices
  9. Manual Pull Station
  10. Series Addressable Devices
  11. Section 2: Wiring Requirements
  12. Measuring Resistance & Length
  13. Four-Wire SLC Style 6 & 7 (Class A)
  14. Shield Wire Termination
  15. Control Panel Terminal Blocks
  16. MS-9050UD
  17. Section 3: SLC Circuits without Isolators
  18. NFPA Style 6 SLC
  19. Section 4: SLC Circuits with Isolators
  20. Wiring an Isolator Module
  21. NFPA Style 4 SLC Using Isolator Modules
  22. NFPA Style 6 SLC Using Isolator Modules
  23. NFPA Style 7 SLC Using Isolator Modules
  24. Section 5: Monitor Modules
  25. Zone Interface Modules
  26. Dual Monitor Module
  27. Setting an SLC address for a Single Point Module
  28. Setting an SLC address for a Multi-Point Module
  29. MMF-300 Wiring Diagrams
  30. Wiring a NFPA Style D IDC with an MMF-300
  31. MMF-300 Wiring for Emergency Alarm System Applications
  32. MMF-300-10 Wiring Diagrams
  33. Wiring a NFPA Style D IDC with an MMF-300-10
  34. MDF-300 Wiring Diagrams
  35. MMF-302 Wiring Diagrams
  36. Wiring a NFPA Style D IDC with an MMF-302
  37. MMF-302-6 Wiring Diagrams
  38. Wiring a NFPA Style D IDC with an MMF-302-6
  39. Section 6: Control Modules
  40. Wiring a CMF-300 Module
  41. Wiring a Style Z NAC (Four-Wire) with Addressable Control Modules
  42. Setting NACs as Style Y or Style Z
  43. Features Not Supported
  44. Wiring a CMF-300-6 Module
  45. Wiring a Style Z NAC (Four-Wire)
  46. Section 7: Relay Modules
  47. CRF-300-6 Circuit Board Information
  48. Setting an SLC address for a CRF-300-6 Module
  49. Section 8: Multiple Input/Output Modules
  50. Wiring a CDRM-300 Module (Form-C Relay)
  51. Description
  52. Section 9: Intelligent Detector Bases and Wireless Gateway
  53. Wiring an Isolator Base
  54. Wiring a Sounder Base
  55. W-GATE Powered by the SLC
  56. W-GATE Powered by a Regulated, External +24VDC Power Source
  57. Section 10: Addressable Beam Detectors
  58. Wiring a Beam Detector
  59. Section 11: Addressable Manual Pull Station
  60. Appendix A: Power Considerations
  61. A.2: Supervising 24 VDC Power
  62. Appendix B: Surge Suppression
  63. B.2.1: Wiring Diagram for MS-9200
  64. B.2.2: Wiring Diagram for MS-9600, MS-9600LS, MS-9600UDLS, MS-9200UD, MS-9200UDLS, and MS-9050UD
  65. C.1: CRF-300
  66. C.2: CMF-300 and MMF-302
  67. C.3: MMF-300
  68. C.4: MDF-300
  69. D.1: B350LP or B501 Detector Base
  70. D.2: B224BI Isolator Base
  71. D.4: B501BH(-2) and B501BHT(-2) Sounder Bases
  72. Appendix E: Canadian Versions of SLC Devices
  73. Index