red lion PAXTM Manual
Also see for PAXCK: Manual
Contents |
Inside US: +1 (877) 432-9908 Bulletin No. PAXCK-JOutside US: +1 (717) 767-6511 Drawing No. LP0524www.redlion.net Released 2018-05-15-1-MODEL PAX ‐ 1/8 DIN PRESET TIMER (PAXTM) & REAL‐TIME CLOCK (PAXCK)• 6-DIGIT 0.56" RED SUNLIGHT READABLE DISPLAY• 4 SEPARATE DISPLAYS (TIMER, COUNTER, REAL-TIME CLOCK,AND DATE)• CYCLE COUNTING CAPABILITY• PROGRAMMABLE FUNCTION KEYS/USER INPUTS• FOUR SETPOINT ALARM OUTPUTS (W/OPTION CARD)• COMMUNICATION AND BUS CAPABILITIES (W/OPTION CARD)• BUS CAPABILITIES: DEVICENET, MODBUS AND PROFIBUS-DP• CRIMSON® PROGRAMMING SOFTWARE• NEMA 4X/IP65 SEALED FRONT BEZELGENERAL DESCRIPTIONThe PAXTM (PAX ® Timer) and PAXCK (PAX ® Clock/Timer) offer manyfeatures and performance capabilities to suit a wide range of industrialapplications. Both can function as an Elapsed Timer or Preset Timer,while the PAXCK also offers Real-Time Clock with Date capability. Theoption cards allow the opportunity to configure the meter for the presentapplication, while providing easy upgrades for future needs.Both units can function as an Elapsed Time Indicator. By using twoseparate signal inputs and 23 selectable timer ranges, the meters can beprogrammed to meet most any timing application. By adding a setpointoption card, they can easily become a dual or quad output preset timer.The PAXCK can also operate as a Real-Time Clock (RTC), with theReal-Time Clock Card already installed. The meter is capable ofdisplaying time in 12 or 24-hour time formats. The 12-hour format can bedisplayed in hours and minutes, with or without an AM/PM indication or inhours, minutes, and seconds. The 24-hour format can be displayed inhours and minutes or in hours, minutes, and seconds. The PAXCK is alsocapable of a calendar display in which the day, month and/or year can bedisplayed. The meter will recognize leap years, and can automaticallyadjust for Daylight Savings Time. The Real-Time Clock has the ability toexternally synchronize with other PAXCK meters to provide a uniformdisplay network throughout the plant.If the application calls for both a Preset Timer and a Real-Time Clock atthe same time, the PAXCK can handle this requirement as well. Themeter provides up to four different displays, accessed via front panel pushbuttons or external inputs. The displays are Timer (TMR), which displaysthe current timer value; Count (CNT), which displays the current cyclecounter value; Date (DAT), which displays the current programmed date;and Real-Time Clock, which displays the current time. A battery-backedReal-Time Clock card is provided with the PAXCK. This card, whichincludes a lithium coin-cell battery, will maintain the time and date whenmain power is removed.The meters accept inputs from a variety of sources including switchcontacts and outputs from CMOS or TTL circuits. The input can beconfigured to trigger on the edge or level of the incoming pulse. Internaljumpers are available to allow the selection for sinking inputs (active low)or sourcing inputs (active high).The front panel keys and three user inputs are programmable toperform various meter functions. One of the functions includesexchanging parameter lists, allowing for two separate listings of setpointvalues, timer start/stop values, counter start/stop values and RTC daily onand off values.Optional digital output cards provide the meter with up to four setpointoutputs. The cards are available as dual relay, quad relay, quad sinkingtransistor, quad sourcing transistor/SSR drive, or dual triac/dual SSRdrive outputs. The setpoint alarms can be configured to suit a variety ofcontrol and alarm requirements.Communication and Bus Capabilities are also available as optioncards. These include RS232, RS485, Modbus, DeviceNet, and Profibus-DP. Readout values and setpoint alarm values can be controlled throughthe bus. Additionally, the meters have a feature that allows a remotecomputer to directly control the outputs of the meter. With an RS232 orRS485 card installed, it is possible to configure the meter using aWindows® based program. The configuration data can be saved to a filefor later recall.Once the meters have been initially configured, the parameter list maybe locked out from further modification entirely, or the setpoint, timer start/stop values, counter start/stop values, RTC time SET, and DisplayIntensity can be made accessible. This lockout is possible through asecurity code or user input.The meters have been specifically designed for harsh industrialenvironments. With a NEMA 4X/IP65 sealed bezel and extensive testingto meet CE requirements, the meter provides a tough yet reliableapplication solution.SAFETY SUMMARYAll safety related regulations, local codes and instructions that appearin this literature or on equipment must be observed to ensure personalsafety and to prevent damage to either the instrument or equipmentconnected to it. If equipment is used in a manner not specified by themanufacturer, the protection provided by the equipment may be impaired.Do not use this unit to directly command motors, valves, or otheractuators not equipped with safeguards. To do so can be potentiallyharmful to persons or equipment in the event of a fault to the unit.CAUTION: Risk Of Danger.Read complete instructions prior toinstallation and operation of the unit.CAUTION: Risk of electric shock.DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is2.1" (53.4) H x 5.0" (127) W.3.801.95.10 4.10(2.5)(96.5)(49.5)(104.1)1.75(44.5)RSTDSP PAR F1 F2TMRDATCNTSP1 SP3SP2 SP43.60 (91.4)252423222120321 654 87 1110915141319181712 16(44.5)1.75C US LISTEDULRPROC. CONT. EQ.E179259 |
Related manuals for red lion PAXCK
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved