red lion C48TS Manual
Also see for C48T: Instruction manualInstructionsInstruction manual
1O LCD, 7 SEGMENT, 2 LINE, 6 DIGIT DISPLAY, POSITIVEREFLECTIVE OR NEGATIVE TRANSMISSIVE MODELS WITHRED TOP LINE AND GREEN BOTTOM LINE BACKLIGHTINGO SOLID STATE AND RELAY OUTPUT MODELSO FIELD REPLACEABLE RELAY OUTPUT BOARDSO STATUS INDICATORS FOR OUTPUTSO NEMA 4X/IP65 SEALED FRONT BEZELO PROGRAMMABLE USER INPUTS AND FRONT PANELFUNCTION KEYO PARAMETER SECURITY VIA PROGRAMMABLE OPERATORACCESS PRIVILEGES AND PROTECTED VALUE MENUO HORIZONTAL OR VERTICAL STACKING OF MULTIPLE UNITSO 85 to 250 VAC or 18 to 36 VDC/24 VAC POWERED UNITSO RS485 SERIAL COMMUNICATIONS OPTIONO CHOICE OF NUMERIC DATA ENTRY MODESDESCRIPTIONThe Model C48 Timer is available in Single or Dual Preset models. TheC48T features a 7 segment, 2 line by 6 digit reflective or backlit LCD display.For the backlit versions, the main display line is red and shows the timer value.The smaller secondary display line is green, and can be used to view the presetvalues or output time values.The C48 timer can be configured for a variety of different operating modesto meet most timing application requirements. Twelve timing ranges areavailable from thousandths of a second to hours and minutes. Decimal Pointsare used to separate the time units (hours, minutes, seconds). Timing can becumulative or can reset and start upon each power cycle. “On Delay” or “OffDelay”, “Single Shot”, “Repetitive auto cycling” modes are all supported.The Timer can also be configured to Continue or Stop timing upon reachingPreset. The display can be programmed to stop at the preset value (Reset to Zeromode) or zero (Reset to Preset mode), or automatically reset to zero or presetand hold. Once stopped, the timer can be restarted by manually resetting it, orit can be programmed to restart when power is reapplied.The C48 Timer has a Run/Stop Input, 3 programmable User Inputs, and aprogrammable front panel function key. The Run/Stop and User Inputs can beconfigured as sinking (active low) or sourcing (active high) inputs via a singleplug jumper. The user inputs and the front panel function key can be configuredto provide a variety of functions.Four front panel push-buttons are used for programming the operating modesand data values, changing the viewed display, and performing userprogrammable functions, e.g. reset, etc. The C48T can be configured for one oftwo numeric data entry methods, digit entry or automatic scrolling. The digitentry method allows for the selection and incrementing of digits individually.The automatic scrolling method allows for the progressive change of onethrough all digit positions by pressing and holding the “up” or “down” button.The Dual Preset models are available with solid-state or Relay outputs. TheSingle Preset model has a solid-state and relay output in parallel. All solid-stateoutputs are available in a choice of NPN current sinking or PNP currentsourcing, open-collector transistor outputs. All relay output boards are fieldreplaceable.The optional RS-485 serial communication interface provides two-waycommunication between a C48 and other compatible equipment such as aprinter, PLC, HMI, or a host computer. In multipoint applications (up to thirty-two), the address number of each C48 on the line can be programmed from 0 to99. Data from the C48 can be interrogated or changed, and alarm output(s) maybe reset by sending the proper command code via serial communications. PCsoftware, SFC48, allows for easy configuration of controller parameters. Thesesettings can be saved to disk for later use or used for multi-controller downloading. On-line help is provided within the software.The unit is constructed of a lightweight, high impact plastic case with atextured front panel and a clear display window. The front panel meets NEMA4X/IP65 specifications when properly installed. Multiple units can be stackedhorizontally or vertically. Modern surface-mount technology, extensive testing,plus high immunity to noise interference makes the C48 Timers extremelyreliable in industrial environments.SAFETY SUMMARYAll safety related regulations, local codes and instructions that appear in themanual or on equipment must be observed to ensure personal safety and toprevent damage to either the instrument or equipment connected to it. Ifequipment is used in a manner not specified by the manufacturer, the protectionprovided by the equipment may be impaired.Do not use this unit to directly command motors, valves, or other actuatorsnot equipped with safeguards. To do so, can be potentially harmful to personsor equipment in the event of a fault to the unit.C48T SERIES - 1/16 DIN TIMERSMODEL C48TS - SINGLE PRESETMODEL C48TD - DUAL PRESETDIMENSIONS “In inches (mm)” PANEL CUT-OUTBulletin No. C48T-CDrawing No. LP0394Revised 3/01Tel +1 (717) 767-6511Fax +1 (717) 764-0839www.redlion-controls.comUL Recognized Component,File # E137808 |
Related manuals for red lion C48T
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved