Page: 54 Model MRC88m / MRAUDIO8x8m© 2009 Xantech CorporationFigure 27: Editing CommandsIR IN ZONE(ADVANCED/EXPANDED)Highlighting a single command in the Macro Command List and selecting Ir In Zone from the pop-upmenu will display another list with Current Zone and Zones 1 thru 8 as choices (for EXPANDED systems,Zones 1 thru 16 are available for selection).Current Zone: Selecting Current Zone will route the individual highlighted command from the issuingKeypad to the corresponding Zone IR port on the rear of the Controller Amplifier - Figure 3-(28) as wellas the In-Zone IR Emitter port on the rear of the Keypad if enabled - Figure 5-(22) (IR Loop-BackFeature).Zone 1 (thru 8):(EXPANDED Zones 1 thru 16): Selecting any of these Zones in the list will route the highlighted IRcommand to the selected Zones IR emitter port on the rear of the MRC88m Controller as well as the In-Zone IR Emitter port on the rear of the Keypad (if enabled) regardless of which zones keypad issued thecommand. (i.e. if Zone 2 is selected from the pop-up menu, pressing the associated button on Zone 1’skeypad will issue that individual command out of the Zone 2 Emitter Ports thereby controlling somethingin Zone 2 while in Zone 1). Each command in the macro command list can be assigned to a differentEmitter Port if so desired.SOURCE O UTPUT(ADVANCED/EXPANDED)Highlighting a single command in the Macro Command List and selecting Source Output from the pop-upmenu will display another list with Current Source and Sources 1 thru 8 as choices.Current Source: Selecting Current Source will route the individual highlighted command from the issuingKeypad to the Source Emitter Output port - Figure 3-(26) of the corresponding active source on thezones keypad.Source 1 (thru 8): Selecting any of these source selections will route the individual highlighted commandfrom the issuing Keypad to the selected Source Emitter Output port - Figure 3-(26) regardless of theactive source on that zones keypad.