38DIP Switch ChartSwitch DIP Switch NumberBank Purpose Function 1 2 3 4 5 6 7 8 9 10S1 Heat OffDelay90 Seconds Off Off --- --- --- --- --- --- --- ---120 Seconds On Off --- --- --- --- --- --- --- ---150 Seconds* Off On --- --- --- --- --- --- --- ---180 Seconds On On --- --- --- --- --- --- --- ---ThermostatSetup1-Stage T-Stat --- --- Off --- --- --- --- --- --- ---2-Stage T-Stat --- --- On --- --- --- --- --- --- ---5-Min Delay --- --- --- Off --- --- --- --- --- ---Auto Delay --- --- --- On --- --- --- --- --- ---S2 Bus BIAS BIAS On* On* --- --- --- --- --- --- --- ---TERM Bus Termination --- --- On* --- --- --- --- --- --- ---S3 CoolingSpeed TapA Off Off --- --- --- --- --- --- --- ---B On Off --- --- --- --- --- --- --- ---C Off On --- --- --- --- --- --- --- ---D* On On --- --- --- --- --- --- --- ---Adjust Taps Normal* --- --- Off Off --- --- --- --- --- ---10% --- --- On Off --- --- --- --- --- ----10% --- --- Off On --- --- --- --- --- ---Normal --- --- On On --- --- --- --- --- ---S4 RampingProfilesA* --- --- --- --- Off Off --- --- --- ---B --- --- --- --- On Off --- --- --- ---C --- --- --- --- Off On --- --- --- ---D --- --- --- --- On On --- --- --- ---HeatingSpeed TapA --- --- --- --- --- --- Off Off --- ---B* --- --- --- --- --- --- On Off --- ---C --- --- --- --- --- --- Off On --- ---D --- --- --- --- --- --- On On --- ---S5 DEHUM Disabled* --- --- --- --- --- --- --- --- Off UnusedEnabled --- --- --- --- --- --- --- --- On Unused*Indicates factory setting--- Not applicableGoodman 118 Long HIGH VOLTAGE!WARNINGTo avoid personal injury or death due to electrical shock, disconnect electrical powerbefore performing any service or maintenance.