Control connectionDS 400-2 04/2019 - V01 36Digital input5 Control connection5.1 Digital input6 Opto-inputDS-BAx-DPC/E-DS-400-digi-in-2Input voltageH-level (On) +10 bis +30 VL-level (Off) <+6 VInput current Max. 7,5 mARatet voltage / cure 24 V/6 mAReference ground GNDE (X1:10)The enable input (FRG/RUN) and the input for the rotating field enable (RFE) are fixed, theycannot be programmed.Without the enable FRG/RUN the servo-drive is electronically disabled (no PWM pulses).Without the rotating field enable RFE the rotating field of the output stage is additionallyelectronically disabled (2 nd disable channel). The drive is free of torque (no holding torque).The remaining four digital inputs can be programmed.The inputs LMT1 (X1:5) and LMT2 (X1:6) are preferably to be used as inputs of the output stageswitch.Input Connection Function StateFRG/RUN X1:7 Enable fixedRFE X1:18 Rotating field enable fixedEND1/LMT1 X1:5 Output stage switch 1/DigitalinputprogrammableEND2/LMT2 X1:6 Output stage switch 2/DigitalinputprogrammableDIN1 X1:11 Digital input 1 programmableDIN2 X1:12 Digital input 2 programmableExternal voltage supply for the inputs and outputsDS-BAx-DPC/E-DS-400-LogiX1:5 END1/LMT1X1:6 END2/LMT2X1:7 FRG/RUNX1:11 DIN1X1:12 DIN2 VCCPAx3k91k5100nF100nFDigital10...30V=InputDSxx/BAxxX1:18 RFEDigital inputLimit switch 1Limit switch 2EnableDigital Input 1Digital Input 2Rotation-enable(X1:E)(X1:F)(X1:G)(X1:L)(X1:M)(X1:T)(IP65)+24V for the logic and the auxiliaryvoltageGNDE logic ground