30A1683) Use the “L” shaped brush to push the sediment through the drain valve to keep the drain clear. Hose off the heatexchanger and vat walls until all sediment and debris has been flushed through the drain into the filter tub.4) Turn the RIGHT HAND Topside Shortening Return Lever 1⁄4 turn counter clock wise; then CAREFULLYremove the Wash Down Hose MALE In-Line Plug from the TOPSIDE FEMALE SOCKET by depressingthe Topside Socket Release Knob.5) Hang the Wash Down Hose in an up-right position so shortening can drain into a metal container; then proceedto paragraph B 1 below.b. Fryer WITH an Automatic Vat Cleaner (AVC).1) With the Drain Valve in the OPEN position, CAREFULLY place the AVC (Spray Blaster) on the fryer’s TOPSIDEHANGER BRACKET and SECURELY connect the MALE In-Line Plug on the AVC to the TOPSIDE FEMALESOCKET.2) Turn the RIGHT HAND Topside Shortening Return Lever 1⁄4 turn counter clock wise to allow shortening in thefilter tub to be discharged into the vat through the four (4) nozzles in the bottom of the spray blaster, flushingsediment and debris through the drain valve. When all sediment and debris has been flushed from the vat, turn theTopside Shortening Return Lever 1⁄4 turn clock wise, remove the male in-line plug on the Spray Blaster from theTopside Female Socket by depressing the Topside Release Knob.3. CAREFULLY remove the HOT Automatic Vat Cleaner from the hanger bracket, and THOROUGHLY clean it in a3 compartment sink.4. Proceed to paragraph B 1 below.������� ������������� ����������� �������������������� ������������ ��� ��������������� ������B. POLISHING SHORTENING1. Set a timer for the amount of time established for POLISHING shortening, then turn the VAT SHORTENING RETURNLEVER 1/4 TURN COUNTER CLOCKWISE to allow shortening to circulate through the system to POLISH the shortening.CAUTION: DO NOT POLISH THE SHORTENING MORE THAN THE ESTABLISHED TIME AS IT WILL PUMP EXCESS AIRINTO THE SHORTENING CAUSING SHORTENING BREAKDOWN.2. At the end of the established time, TURN the VAT SHORTENING RETURN LEVER 1/4 TURN CLOCKWISE, turn theDRAIN VALVE HANDLE to the closed UP position; replace the grill in the fryer; then TURN the Vat Shortening RETURNLEVER 1/4 COUNTER CLOCKWISE to automaticlly return shortening in the filter tub to the fryer vat.3. When all shortening in the filter tub has been returned to the fryer, TURN the VAT SHORTENING RETURN LEVER, 1/4TURN CLOCKWISE check and if necessary add fresh shortening so shortening is level with the middle line of the letter “E”in the word LEVEL of the shortening level mark on the rear wall of the fryer.4. Remove the Filter Tub Assembly by pressing the DOCKING RELEASE HANDLE and pulling the STANDPIPE DOCKINGHANDLE ASSY away from the FEMALE Bulkhead Socket adjacent to the Drain Valve; then THOROUGHLY clean,assemble and replace the Filter Tub Assembly in the fryer cabinet.Page 37 of 56