30A168A. UNPACKING: Check that the container is upright. Use an outward prying motion – DO NOT USE A HAMMER - to remove thecarton. Check the fryer for visible damage; if such damage has occurred do not refuse shipment, but contact the carrier and filethe appropriate freight claims.B. INSTALLING: Roll the assembled fryer into the building, to it’s operating location.WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSEPROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCEINSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.C. LEVELING:1. When the fryer is placed in its operating location check to be sure it is level. If not, loosen the casters and insert the appropriate number of shim plates between leg and caster plates then retighten the caster bolts.2. If the floor is smooth and level, adjust to the high corner and measure with a spirit level. If the floor is uneven or has adecided slope, level the unit with metal shims.NOTE: A caster may not return exactly to the same position after being moved, which may require re-leveling after each move.3. Connect the gas manifold to the building gas supply line by means of a CSA International APPROVED flexible gas line asshown in the figure below.NOTE: CONNECT-IT inc. 3⁄4" (19mm), 1" (25mm) and 1 1⁄4" (32mm) flexible gas hose 4 feet long (1219mm) with a quickdisconnect coupling on one end is available from Ultrafryer Systems under PN 24322 (3⁄4" (19mm) hose), PN 24323(1" (25mm) hose) and PN 24456 (1 1⁄4" (32mm) hose). These hoses are euipped with a fusible link, which melts at361°F (183ºC) that will SHUT OFF the gas supply when it melts. A 44" (1119mm) long restraining device is alsoavailable under PN 24324.CAUTION: THE BUILDING GAS SUPPLY LINE MUST BE SIZED TO PROVIDE THE VOLUME OF GAS REQUIRED FORPROPER OPERATION AS EXPLAINED ON THE PREVIOUS PAGE.WARNING: THE RESTRAINT DEVICE (ITEM 9) MUST BE INSTALLED TO ASSURE TENSION CANNOT BE PLACED ONTHE FLEXIBLE GAS LINE OR FITTING.1. BUILDING GAS SERVICE LINE 6. APPLIANCE MANIFOLD/NIPPLE2. MAIN GAS CUT-OFF VALVE 7. EYELET FASTENERS3. CONNECT-IT QUICK-DISCONNECT 8. SPRING HOOK4. FLEX-CON CONNECTOR 9. RESTRAINING CHAINTYPICAL GAS CONNECTIONPage 10 of 56