Configure StratagySMDI Serial Integration4-34 Stratagy I&M 06/02Step 2: Connect SMDISMDI connections use a RS-232 cable to connect the telephone system to one of Stratagy’s serialports.For a Centrex installation, a data modem provides the SMDI connection. SMDI interface requiresthat the Strata DK have a WSIU, TSIU, PIOU, PIOUS, RSSU or RSIU PCB installed.Consult the Strata DK Installation and Maintenance Manual for installation instructions.Step 3: Test SMDIAfter the SMDI feature has been enabled in Stratagy and the serial link has been established withthe COM ports, the SMDI link can be tested.Initial testing can be done by making test calls into Stratagy. Program a User ID with defaultoptions. Use the default System Greeting and default System Busy greetings for the mailbox.1. Make a call into Stratagy from an extension that is the same number as the User ID. Stratagyreceives a Direct Call packet and prompts “Please enter your security code.”Note If the system plays the Company Greeting, then the link is not working. Recheck theinstallation.2. Call forward a telephone All Calls. From another extension, call the forwarded telephone. TheSystem Greeting for the mailbox plays.Note If the system plays the Company Greeting, then the link is not working. Recheck theinstallation.3. Call forward a telephone for Busy. Make the extension busy, then call the busy extension fromanother telephone. The System Busy Greeting plays.Note If the system plays the Company Greeting, then the link is not working. Recheck theinstallation.4. If Steps 1, 2 and 3 were successful, make another call from an internal extension (that has aUser ID assigned on the system) to the forwarded extension, and leave a message.5. Log on to the User ID that has the message. The header information for the message shouldinclude the User ID number of the extension that left the message.Play the message. If these tests are successful, the SMDI integration is working properly. Ifthese tests fail, then the link must be monitored to validate whether the data is being sent fromthe host phone system or the data is not being processed correctly by Stratagy. Proceed to Step4.Step 4: (Optional) Validate the LinkIf the tests in Step 3 on page 4-34 fail, then the link must be monitored to validate whether the datais being sent from the host phone system or the data is not being processed correctly by Stratagy.To validate the link, you must perform the following procedure.Note For further assistance, contact Toshiba Technical Support.1. Connect a portable or desktop PC to the RS-232 serial connection from the Host telephonesystem.Note The PC must have a communications program such as Microsoft Windows Terminal orProComm. The data packets are in ASCII format.2. Make calls into the Stratagy voice ports. As calls ring in, data packets should be received on thePC. If packets are being sent, then Stratagy is not processing them correctly. Continue to Step 4.