Telephone Button ProgrammingButton Programming ExamplesStrata CIX/CTX Telephone Button Programming 11/04 1-5Telephone ButtonProgrammingButton Programming ExamplesThe following examples show you how to use the Strata CTX button programming interface. Toshiba highlyrecommends the use of Strata CTX WinAdmin to meet the demands of your telephone systemprogramming.Suppose a customer needed to assign a DKT Station to a PDN. Based on the Identify Program Sequencesin Chapter 1 of the Programming Manual Volume 1, you can immediately identify the Program numbersand sequence required to complete this basic task. Login to the Button Programming Mode using thedirections on Page -7 and follow the steps below.Program 100Reference ìProgram 100î on page 11. For this example, an eight station BDKU PCB is assigned to Slot 01/Cabinet 01 (xxyy).1. Enter programming mode. See ìStep 1: Enter Program Mode on page 1-7."2. At the PROG= prompt enter 100 and press Hold.3. At the EQUIP= prompt enter 0101 (xxyy) and press Hold.“Program 100” on page 11 tells us that a three digit PCB code (nnn) is required. From the table, “PCBCodes” on page 1-12, we can derive that the PCB code for a BDKU is “017.” Furthermore, the“Program 100” table shows us the button sequence required for programming a BDKU in the fourthrow of the table.4. Press FB01. Enter 017 and press Hold.“Program 100” on page 11 also informs us that an “n” value is required to complete the PCBassignment. These “n” values are listed in the column titled “Value(s).” When you look in the fourthrow of the “Value(s)” column there are five “n” value choices. For this example, select “2. 8 DKT noOCA.”5. Press FB03. Enter 2 and press Hold twice.6. Press ##Hold to return to the PROG= prompt.Program 200Reference ì200 Series Programsî on page 1-28. A DKT assignment (DN = 1000) is made to Circuit 01,Slot 01, and Cabinet 01 for the BDKU card installed in Step 1 above.1. Enter programming mode. See ìStep 1: Enter Program Mode on page 1-7."2. At the PROG= prompt enter 200 and press Hold.3. At the DN= prompt enter 1000 (n) and press Hold.4. Press FB01. At the EQUIP= prompt enter 010101 (xxyyzz) and press Hold.5. Press FB02. Press 1 to select a DKT and press Hold.6. Press FB03. Press 1 to select Extension as the Circuit Type and press Hold.For this example, only the above FBs need to be assigned. Press Hold again before proceeding to thenext step.7. Press ##Hold to return to the PROG= prompt.Note Additional assignments can be made to fine tune this DKT assignment. If specific assignments arenot made, the system automatically assigns the default value.