Step 2: Remove the motor/generator assembly from the machine.g035728Figure 1261. Operator’s seat 3. Motor/generator controller (mounted to motor/generatorassembly)2. Motor/generator connector P37Remove the motor/generator assembly from the machine. Refer to Chapter 5 of the 5010-H Service Manual.See Figure 126.Step 3: Remove the controller from the motor/generator.Remove the controller from the motor/generator. Refer to Chapter 5 of the 5010-H Service Manual.Step 4: Inspect the wiring between the motor/generator and thecontroller.The motor/generator and the controller each have cabling that connects to the other component. Inspect thewiring between the controller and the motor/generator.Pass The wiring between the controller and the motor/generator passed inspection. Go to Step 5.Fail The wiring between the controller and the motor/generator did not pass inspection. Only repairwiring that has worn insulation or a recessed connector pin. Replace all components that havedamaged, burned, or broken wiring. Go to Returning the Machine to Service (page 22) and followthe steps listed.Step 5: Install a replacement controller onto the motor/generator.Refer to Chapter 5 of the 5010-H Service Manual and follow the steps listed.Step 6: Install the motor/generator assembly.Refer to Chapter 5 of the 5010-H Service Manual and follow the steps listed.220