Greensmaster 3200/3200–DHydraulic System Page 5 – 701. Bulkhead nut2. Bulkhead nut3. Cap screw4. Hose assembly5. Reel motor6. Bulkhead bracket7. Hydraulic tube8. Hose assembly9. Washer10. Spacer11. Rubber grommet12. Hydraulic fitting13. 90_ Hydraulic fitting14. Bulkhead bracket15. R–clamp16. Hose assembly17. Cap screw18. Lock nut19. Flat washer20. Hydraulic tube21. Hydraulic tube22. O–ring23. O–ring24. O–ring25. O–ring26. Hose assembly27. O–ring28. Bulkhead T–fitting29. Hose retainer30. Hose assembly31. Hydraulic tube32. Hydraulic tube33. Lock nut34. Double tube clamp35. Cap screw36. Cable tieFigure 568426379164 1213 51319 10111714153191820212223222324251 91011269 2728 272729303133233343536FRONTRIGHTRemoval (Fig. 55 and 56)1. Before removing any parts from the hydraulic sys-tem, park machine on a level surface, engage parkingbrake, lower cutting units, and stop engine.CAUTIONOperate all hydraulic controls to relieve sys-tem pressure and avoid injury from pressur-ized hydraulic oil. Controls must be oper-ated with the ignition switch in RUN and theengine OFF. Return ignition switch to OFFwhen pressure has been relieved. Removekey from the ignition switch.2. Remove reel motor from the cutting unit (see Cut-ting Unit Removal and Installation in Chapter 7– CuttingUnits).3. Clean reel motor, hydraulic fittings, and hose con-nections.Note: The position of hydraulic fittings on the reel mo-tor is critical to properly reconnecting hydraulic hoses.4. Label all hose connections for reassembly pur-poses. Matchmark reel motor and all hydraulic fittingsfor reassembly purposes.5. Remove hose connections from the hydraulic fit-tings on the reel motor. Allow hydraulic oil to drain fromhoses into a suitable container. Put caps or plugs onends of hoses to prevent contamination.6. Remove hydraulic fittings and O–rings from the reelmotor. Put caps or plugs in motor openings to preventcontamination.Installation (Fig. 55 and 56)1. Make sure hydraulic fitting ports and O–ring sealingsurfaces on the reel motor are clean.2. Make sure hydraulic fittings are clean. Inspectthreads and sealing surfaces of fittings. Replace anyworn or damaged fittings.