13·24(2) F-201F-201PORTSymbolTransfer task number "n" and PC memory data (set the top addressusing @S) to a ZW/JW-20CM at port "n."FunctionContents of @S (Set S to S+6 using the PC)D to D+2: Set the top address for sending data using the file numberand file address.D+3: Number of data bytes to transfer from the PC to JW-20CM.Set to 000 to 255(D) . (000(D) equals 256 bytes.)D+4 to D+6: Reserved area. Set 000(8).D+7: Station number at which data is sent. Set from ZW/JW-20CMD+10(8) : Station number at which data is sent. Set from ZW/JW-20CMD+11(8) : Reserved area. Status from a port (not fixed). MRead from a portOperation contentsSet to TASK 1.Setting range forTASK "n"Set a port number for the PC basic rack panel on which the ZW/JW-20CM is installed.(Ex.: JW-13BU)Setting range forPORT "n"F-201POR TASKn PORTn @ DDD+1D+2D+3nn+1n+2n+3D+4D+5D+6D+7D+10 (8)D+11 (8)File address (lower bit)(upper bit)File numberNumber of bytes transferredReceive station's station numberCompleted receiving flag000 (8)000 (8)000 (8)Reserved (not fixed)ReservedTop address forsending dataResisterNot fixed7 6 5 4 3 2 1 07 6 5 4 3 2 1 0FlagJW-20CMControl modulePower modulePort No.