Sealey Professional TOOLS AK2018 Instructions Manual
AK2018 - 3 - 220206INSTRUCTIONS FOR:3 IN 1 METAL, VOLTAGE AND STUD DETECTORModel: AK2018Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructionsand properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONALREQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THEPURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURYAND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.Combined unit for the accurate detection of live or dead electricity cables, water or gas pipes and woodenstuds or battens. Powered by a 9V battery (not supplied) the detector will, with red and green LED displaysand an audible signal, show the presence of metal, electricity and studs or battens.1. DESCRIPTION2. SAFETY! When the unit gives a ëno voltageí reading (no flashing of red LED and beeping of the buzzer whentouching the conductor), check the unit on a known voltage source BEFORE touching the conductor.! Intended for indoor use only - DO NOT get the detector wet.! The unit will not detect electricity in shielded conductors i.e. those in a metal conduit. In suchcases it will indicate only the presence of metal.3. OPERATION! Warning! Ensure that you read, understand and apply the safety instructions before attempting to use thedetector.Note: Remove the battery cover. Install a 9V PP9 battery. Refit the battery cover. Refer to Fig. 2.3.1 Metal Detection3.1.1 Rotate the blue knob (Voltage/Metal Detector) fully downwards and move the selector switch to the Voltage/Metal Detectionposition. The green LED will illuminate. Make sure that the unit is well away from any metal or current carrying conductorand hold it as shown in Fig. 3.3.1.2 Turn the blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blueknob slowly until the indicators just go off . The unit is now ready for use.3.1.3 Hold the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. The red LED and a continuousbuzzer tone will come on when a metal object is in the vicinity.3.1.4 If the indicators do not come on, or will not go off, after the unit has been switched on, the detector requires adjustment.For adjustment details, please refer to Section 3.5.3.2 Voltage Detection3.2.1 Turn the blue knob (Voltage/Metal Detector) downwards and move the selector switch to the (Voltage/Metal Detector)position. The green LED will illuminate immediately. Make sure that the unit is well away from any metal or current carryingconductor.3.2.2 Turn the blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blueknob slowly until the indicators just go off . The unit is now ready for use.3.2.3 Hold the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. Current-carrying conductors will beshown by a flashing red LED and the sound of an interrupting buzzer.3.2.4 If the indicators do not come on, or will not go off after the unit has been switched on, the detector requires adjustment.For adjustment details, please refer to Section 3.5.Fig. 2Fig. 3Fig. 4AK2018 - 3 - 220206INSTRUCTIONS FOR:3 IN 1 METAL, VOLTAGE AND STUD DETECTORModel: AK2018Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructionsand properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONALREQUIREMENTS, WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THEPURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURYAND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.Combined unit for the accurate detection of live or dead electricity cables, water or gas pipes and woodenstuds or battens. Powered by a 9V battery (not supplied) the detector will, with red and green LED displaysand an audible signal, show the presence of metal, electricity and studs or battens.1. DESCRIPTION2. SAFETY! When the unit gives a ëno voltageí reading (no flashing of red LED and beeping of the buzzer whentouching the conductor), check the unit on a known voltage source BEFORE touching the conductor.! Intended for indoor use only - DO NOT get the detector wet.! The unit will not detect electricity in shielded conductors i.e. those in a metal conduit. In suchcases it will indicate only the presence of metal.3. OPERATION! Warning! Ensure that you read, understand and apply the safety instructions before attempting to use thedetector.Note: Remove the battery cover. Install a 9V PP9 battery. Refit the battery cover. Refer to Fig. 2.3.1 Metal Detection3.1.1 Rotate the blue knob (Voltage/Metal Detector) fully downwards and move the selector switch to the Voltage/Metal Detectionposition. The green LED will illuminate. Make sure that the unit is well away from any metal or current carrying conductorand hold it as shown in Fig. 3.3.1.2 Turn the blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blueknob slowly until the indicators just go off. The unit is now ready for use.3.1.3 Hold the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. The red LED and a continuousbuzzer tone will come on when a metal object is in the vicinity.3.1.4 If the indicators do not come on, or will not go off after the unit has been switched on, the detector requires adjustment.For adjustment details, refer to Section 3.5.3.2 Voltage Detection3.2.1 Turn the blue knob (Voltage/Metal Detector) downwards and move the selector switch to the Voltage/Metal Detectorposition. The green LED will illuminate immediately. Make sure that the unit is well away from any metal or current carryingconductor.3.2.2 Turn the blue knob upwards until the indicators come on (red LED illuminated and buzzer activated). Reverse the blueknob slowly until the indicators just go off . The unit is now ready for use.3.2.3 Hold the unit as shown in Fig. 4 and move it sideways (horizontally) across the wall. Current-carrying conductors will beshown by a flashing red LED and the sound of an interrupting buzzer.3.2.4 If the indicators do not come on, or will not go off after the unit has been switched on, the detector requires adjustment.For adjustment details, refer to Section 3.5.Fig. 2Fig. 3Fig. 4Fig. 1 Fig. 1 |
Related manuals for Sealey Professional TOOLS AK2018
Sealey AK2018.V2 Instructions Manual
Sealey PP4.V2 Instructions Manual
Sealey PP4.V2 Instructions Manual
Sealey PP4.V2 Instructions Manual
Sealey PP4.V2 Instructions Manual
Sealey VS0062 Instructions Manual
Sealey VS600.V2 Instructions Manual
Sealey AK1998.V3 Manual
Sealey VS870 Quick Manual
Sealey VS869 Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved