Sealey PP4.V2 Instructions Manual
Also see for PP4.V2: InstructionsInstructionsInstructions
Detector TransmitterOperating Conditions: 0°C ~ 40°C <80% RH 0°C ~ 40°C <80% RHFrequency Response: 40kHz +/- 2kHz -Output Frequency: - 40kHzBattery: 9V 9VSize: 192 x 50 x 30mm 80 x 56 x 27.5mmWeight: 115g (incl battery) 75g (incl battery)1.1. GENERAL SAFETY INSTRUCTIONS Familiarise yourself with the application, limitations and potential hazards of the tester. Also refer to the vehicle manufacturer’s hand book. Ensure that the tester is in good condition before use. Only use recommended attachments and parts. To use unapproved items may be dangerous and will invalidate your warranty. If the tester receives a sharp knock or blow the unit must be checked by a qualified service agent before using. Keep children and unauthorised persons away from the work area. DO NOT disassemble the tester for any reason. The tester must only be checked by qualified service personnel. WARNING! To avoid damaging hearing, DO NOT set headphones volume too high. DO NOT drop the detector or transmitter. DO NOT tamper with the electronic circuit boards within the dectector or transmitter. DO NOT use the tester outdoors, or in damp, or wet locations and DO NOT use in the vicinity of flammable liquids or gases. DO NOT use the dectector or transmitter near any electrical appliances which emit electromagnetic waves, as this will give a false reading. DO NOT use the tester for a task for which it is not designed. When not in use, store the tester carefully in a safe, dry, childproof location. If the dectector and transmitter are not to be used for long periods, remove the batteries before storing.INSTRUCTIONS FOR:ULTRASONIC LEAK DETECTORMODEL No: PP4.V2Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions andproperly maintained, give you years of trouble free performance.1. SAFETY INSTRUCTIONSIMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSEDAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.3. OPERATION2. INTRODUCTION & SPECIFICATIONQuick and simple location of air, water or dust leaks. Place the transmitterin the vehicle and close the doors and windows. Trace the detector aroundoutside of the screen, windows and door seals to locate the leak. Includesadjustable headphones for detector. Transmitter and detector powered by9V Lithium batteries. Supplied in carry-case. WARNING! Ensure the headphone volume setting is set to low before operating the unit.3.1. Operating in Passive Mode.3.1.1. Insert the headphones plug into the jack (fig.1.7) and put on the headphones.3.1.2. Press and hold down the TEST button (fig.1.6), the POWER LED will light (fig.1.4). A ticking tone will be heard through theheadphones, adjust the volume of the headphones to a suitable level (fig.4). Adjust the sensitivity control to eliminate external noise(fig.2).3.1.3. Holding down the TEST button, move the detector probe around the joint or seal of the suspected area. If a leak is detected theticking tone frequency will increase and the "LEAK" LED will also illuminate (fig.1.5). The closer to the leak the higher the frequency ofthe ticking tone.Note: When the PP4 detects a possible leak, move the probe around the suspected leak to determine whether the ultrasonic sound is fromthe leak or from other areas. Keep the probe as close as possible to the test area and move the probe slowly.3.1.4. Repair the leak and recheck with the detector.3.1.5. Once testing is complete release the TEST button.Note: There are many factors involved in the ultrasonic leak detection, such as the pressure within the vessel, the size and shape of thehole, temperature etc. In some cases the ultrasonic sound caused by the leak may be very weak, so the sensitivity will need to be setat the highest level. If the ultrasonic sound is too intense, the ticking tone frequency will be high, the sensitivity should be adjusteddown to an acceptable level. Noisy environments may also increase the ticking tone frequency, adjust the sensitivity down to anacceptable level.3.2. Operating in Active Mode3.2.1. Switch on the transmitter (see fig.1.1 & fig.3), the "POWER" LED will illuminate (fig.1.3).3.2.2. Place the transmitter inside the compartment to be checked and close the compartment. The ultrasonic sound generated by thetransmitter (fig.1.2) will leak though any orifice or faulty seal.3.2.3. Scan the the outside of the compartment with the detector. Any leaks from the compartment can be easily detected and pinpointed.3.2.4. When the check is completed remove and turn off the transmitter.PP4.V2 Issue No: 2(L) - 08/01/14Original Language Version© Jack Sealey Limited |
Related manuals for Sealey PP4.V2
Sealey PP4.V2 Instructions Manual
Sealey PP4.V2 Instructions Manual
Sealey PP4.V2 Instructions Manual
Sealey VS600.V2 Instructions Manual
Sealey AK2018.V2 Instructions Manual
Sealey VS0062 Instructions Manual
Sealey Professional TOOLS AK2018 Instructions Manual
Sealey AK1998.V3 Manual
Sealey VS870 Quick Manual
Sealey VS869 Quick Start Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved