23User’s Guide225. Confirmation Matter in Times ofAbnormality OccurrenceSymptom Confirmation and Management MattersControl of the camera 1. Check the polarity of the RS-485 indicationpart is not possible. line.2. Check if the address of the camera part hasbeen set up well.The input channel number Set up the address number of the cameraof the Matrix Switcher part and the input channel number of theand the number of the Matrix Switcher to be the same.camera part appear differently.Because I cannot remember In the state in which the RESET button hasthe Password of this been pressed, if you put in again the power,machine, I cannot enter the machine gets into the state freshly out ofthe set-up MENU. the plant, and you can go into the set-up menu.❈ The contents and the circuits in this explanation can be changed due tosuch reasons as the functional improvement of the production.6. SpecificationsITEM SPECIFICATIONCommunication Interface Type RS-485Port Connector Type Modular Type x2, D-SUB x1Baud Rate 1200, 2400, 4800, 9600, 19200, 38400 BPSSAMSUNG, PELCO-D, PELCO-P, VICONPROTOCOL PANASONIC, KALATEL, DIAMOND,AD, PHILIPS,ERNA, VCL TP, TECHWINDisplay LCD 20 ✕ 4 lineLED MENU, PRESET, PATTERN, SCAN,AUTO PAN, RESETSwitching Video Switching SEQUENCE, TOUR, SALVO& Pan/Tilt & Lens Pan left/rightControl Control Tilt up/downIris open/closeFocus far/nearZoom tele/widePreset, Auto pan, Scan, PatternExternal AUX1, AUX2, AUX3, AUX4machinery ControlPower Source DC 9V 600mADimension 315(W) ✕ 205(D) ✕ 65(H)mmWeight 1.1kg (Excluding packaged goods)RS-485 Connector No 3 (Yellow) : DATA “+”,No 5(Red) : DATA “–”D-SUB Connector No 2 : DATA “+”, No 3 : DATA “–”SSC-1000 (gb) 2009.1.8 1:38 PM Page 22