24_ installation requirementsSPECIAL gAS REQUIREMENTS (gAS MODELS SOLD INMASSACHUSETTS)COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS:Gas leaks may occur in your system, creating a dangerous situation.– Gas leaks may not be detected by smell alone.– Gas suppliers recommend you purchase and install a UL-approvedgas detector. Gas detector should be installed in accordance with themanufacturers instructions.• Range must be installed by a qualified plumber or gas fitter by the State ofMassachusetts.• A T-handle manual gas valve MUST be installed in the gas supply line to yourrange.• If a flexible gas connector is used to install your range, multiple flexible gas linesmust not be connected in series.ELECTRICAL REQUIREMENTSTo reduce the risk of fire, electric shock, or personal injury:All ranges• Do not use an extension cord or adapter plug with this range.• This range must be properly grounded.• Check with a qualified electrician if you are in doubt as to whether your rangeis properly grounded.• Do not modify the plug provided with your range—if it doesn¡¯t fit the outlet,have a proper outlet installed by a qualified electrician.• All wiring and grounding must be done in accordance with local codes or, inthe absence of local codes, with the National Electrical Code, ANSI/NFPA No.70 – Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1– Latest Revisions and local codes and ordinances.• Wiring diagram is located on the back of the range. (Inside of the cover backwire)• This range is equipped with an electronic ignition system that will not operateif plugged into an outlet that is not properly polarized.WARNINGWARNING