installation requirements _23INSTALLATION REQUIREMENTSgAS REQUIREMENTSProvide adequate gas supplyThis range is designed to operate at a pressure of 5 in (13 cm) of watercolumn on natural gas or 10 in (25 cm) of water column on LP gas(propane or butane).Make sure you are supplying your range with the type of gas for which it isdesigned. Do not attempt to convert the appliance from the gas specifiedin this manual to a different gas without consulting the gas supplier.This range is convertible for use on natural or propane gas. If you decide to usethis range on LP gas, conversion must be made by a qualified LP installer beforeattempting to operate the range.For proper operation, the pressure of natural gas supplied to the regulator mustbe between 5 in and 13 in (13 cm and 33 cm) of water column.For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and33 cm) of water column.When checking for proper operation of the regulator, the inlet pressure must beat least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.The pressure regulator located at the inlet of the range manifold must remain inthe supply line regardless of whether natural or LP gas is being used.A flexible-metal appliance connector used to connect the range to the gassupply line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in lengthfor ease of installation. In Canada, flexible connectors must be single-wall metalconnectors no longer than 6 ft (183 cm) in length.Do not kink or damage the flexible metal tubing when moving the range.