48Field setting modeEnglishField Setting ModeClassification Function DetailCode(Main+ submenu)Basic Min. Max. Step UnitOthersOuting modeIndoor heatingtemperature 5014 16 16 30 1 °CTemperature of autoheating WL1 water 5017 25 25 ߢߪ 1 °CTemperature of autoheating WL2 water ߪߣߢߧ 25 25 ߢߪ 1 °CTemperature of hotwater Tank ߫ߣߢߧ 35 35 75 1 °CEconomic DHW mode Temperature of hotwater Tank 5021 5 0 40 1 °CSmart grid (Power peakcontrol)Operation 5041 0 (No) 0 1 (Yes) - -Heat source foroperation limit 5042 0 (All) 0 2 1 -Contact Logic 5043 1(High)0(Low) 1 - -Ratio of hot water supplycompare to heatingA/7 (Ratio isdetermined basedon the value of theA)7 means Heatingcapacity=Hot watercapacity5061 7 1 7 1 -Functions that requires setting according to field specification࡛ Code: 10** ࣙUpper and lower temperature limits for Heating (Water out, Room), Cooling (Water out, room), DHW(Tank) mode ࣙ1011: Maximum Value of cooling leaving water temperature setting in wired remote controller ࣙ1012: Minimum Value of cooling leaving water temperature setting in wired remote controller ࣙ1021: Maximum Value of cooling indoor’s room temperature setting in wired remote controller ࣙ1022: Minimum Value of cooling indoor’s room temperature setting in wired remote controller ࣙ1031: Maximum Value of heating leaving water temperature setting in wired remote controller ࣙ1032: Minimum Value of heating leaving water temperature setting in wired remote controller ࣙ1041: Maximum Value of heating indoor’s room temperature setting in wired remote controller ࣙ1042: Minimum Value of heating indoor’s room temperature setting in wired remote controller ࣙ1051: Maximum Value of hot water tank temperature setting in wired remote controller ࣙ1052: Minimum Value of hot water tank temperature setting in wired remote controller