45EnglishField Setting ModeClassification Function DetailCode(Main+ submenu)Basic Min. Max. Step UnitDHWDisinfectionOperation 3041 1 (Yes) 0 (No) 1 - -Operation interval 3042 Fri (5) Sun(0) AllDay (7) - dayStart time 3043 23 0 23 1 hourTarget temp. 3044 70 40 70 5 °CHolding time 3045 10 5 60 5 min.Max. operation time 3046 ߪ 1 24 1 hourSolar heat panel / defrostsignalSolar heat panel H/Pinterlocking / defrostsignal3061 0 0 3 - -Heating Heating modeHeating/hot waterpriority 4011 0 (Hotwater) 0 1(Heating) - -Heating priority 4012 0 -15 20 1 °CHeating Off 4013 35 14 35 1 °COthersOuting modeTemperature of coolingwater oulet 5011 25 5 25 1 °CRoom Temperature ofcooling Mode 5012 30 ߪߣ 30 1 °CTemperature of heatingleaving water 5013 15 15 50 1 °CIndoor heatingtemperature 5014 16 16 30 1 °CTemperature of autoheating WL1 water 5017 15 15 50 1 °CTemperature of autoheating WL2 water ߪߣߢߧ 15 15 50 1 °CTemperature of hotwater Tank ߫ߣߢߧ 30 30 75 1 °CEconomic DHW mode Temperature of hotwater Tank 5021 5 0 40 1 °CSmart grid (Power peakcontrol)Operation 5041 0 (No) 0 1 (Yes) - -Heat source foroperation limit 5042 0 (All) 0 2 1 -Contact Logic 5043 1(High)0(Low) 1 - -