543.6.2 Hanging on the wallCarefully read the following before attempting to hang the unit on a wall, and observe the various limitations specifiedbelow. Be sure to mount the unit so that twisting, bending, or any other deformation does not exceed 4 mm.Shaded areas indicate attachmentpoints for mounting hardware.Special Instruction (Hanging on the wall)(NOTE) Different temperature restrictions apply to the PDK-5011 and PDK-5013. Refer to “4.6 Wall-mounted TiltablePlasma Display Hardware” and “4.7 Wall-mounted Type Tiltable Fixed Plasma Display Hardware”. In wall-mounting installation, allow adequate space (a clearance of 300 mm or more) above and below the monitorset, as well as to the right and left.Operating temperature restrictions✩ Standard single-unit installationDistance from wall (A) B C D Ambient temperature50 mm or less 300 mm or more 300 mm or more 300 mm or more 0 to 35°C50 mm or more 100 mm or more 50 mm or more 50 mm or more 0 to 40 °C✩ Horizontal/vertical, left/right reverse installation (Note that only Examples 2 and 3 apply in caseswhere top and bottom are reversed)* No matter what the distance between the unit and the wall, the unit must be installed in such a way asto ensure free air flow (With no obstructions within a distance of 300 mm from the unit).Distance from wall (A) B C D Ambient temperature50 mm or more 300 mm or more 300 mm or more 300 mm or more 0 to 35°C✩ Requirements when used with PDP-S07-LR speaker systemWhen installed as a single unit, all requirements are the same as those listed above for horizontal/vertical, left/right reverse installation. Note, however, that the figures listed above are to be interpretedas indicating the distance between the speakers and the wall.ABCD D107052.552.525.615.593.42550[433CMX/433MXE]