Serial port configuration task list 173IPLink Software Configuration Guide 15 • Serial port configurationRx abort sequence: 0Rx non octet: 2Rx frame len violation: 0Rx DPLL error: 0Sent frames: 116106Tx good frames: 116106Tx CTS lost: 0Tx underrun: 0StatusLink: UpControl Line: enabledTrue Baudrate: 64000 bpsEnter Frame Relay modeThis section describes how to configure Frame Relay on the serial interface of an IPLink, after setting the basicserial interface parameters according to the previous sections.This procedure describes how to enter the Frame Relay configuration modeMode: Administrator executionExample: Enter Frame Relay modeThe following example shows how to enter into the Frame Relay configuration mode for the serial interface onslot 0 and port 0 of an IPLink.IPLink(cfg)#port serial 0 0IPLink(prt-ser)[0/0]#framerelayIPLink(frm-rel)[0/0]#Configuring the LMI typeFor a Frame Relay network, the line protocol is the periodic exchange of local management interface (LMI)packets between the IPLink device and the Frame Relay provider equipment. If the IPLink device is attachedto a public data network (PDN), the LMI type must match the type used on the public network.You can set one of the following three types of LMIs on the IPLink devices:• ansi for ANSI T1.617 Annex D,• gof for Group of 4, which is the default for Cisco LMI, and• itu for ITU-T Q.933 Annex A.This procedure describes how to set the LMI type.Step Command Purpose1 node(cfg)#port serial slot port Selects the serial interface on slot and port2 node(prt-ser)[slot/port]#framerelay Enters the Frame Relay configuration mode3 node(frm-rel)[slot/port]# Displays the Frame Relay configuration mode prompt