196Wiring to the Connector, CN X5• You can switch the numerator of electronic gear.• By connecting to COM–, you can switch the numerator ofelectronic gear from Pr48 (1st numerator of electronicgear) to Pr49 (2nd numerator of electronic gear)• For the selection of command division/multiplication, referto the table of next page, "Numerator selection ofcommand scaling"• Input of internal speed selection 3 (INTSPD3).• You can make up to 8-speed setups combining INH/INTSPD1 and CL/INTSPD2 inputs. For details of setup,refer to the table of P.131, "Selection of Internal Speed".• This input is invalid.Position/Full-closed controlVelocitycontrolTorque controlTitle of signal Pin No. Symbol Function I/F circuitServo-ON input 29 SIP.193SRV-ON • Turns to Servo-ON status by connecting this input to COM–.• Turns to Servo-OFF status by opening connection to COM–, and currentto the motor will be shut off. • You can select the dynamic brake action and the deviation counterclearing action at Servo-OFF with Pr69 (Sequence at Servo-OFF).1.Servo-ON input becomes valid approx. 2 sec after power-on.(see P.42, "Timing Chart" of Preparation.)2.Never run/stop the motor with Servo-ON/OFF.3.After shifting to Servo-ON, allow 100ms or longer pause before enteringthe pulse command.Electronic gear (division/multiplication) switching input28 SIP.193DIV • Function varies depending on the control mode.Do not enter the command pulse 10ms before/after switching.Deviationcounter clearinput30 SIP.193CL • Function varies depending on the control mode.• Input (CL) which clears the positional deviation counterand full-closed deviation counter.• You can clear the counter of positional deviation and full-closed deviation by connecting this to COM–.• You can select the clearing mode with Pr4E (Counter clear input mode).• Input of selection 2 of internal command speed (INTSPD2)• You can make up to 8-speed setups combining INH/INTSPD1 and CL/INTSPD3 inputs. For details of setup,refer to the table in P.131, "Selection of Internal Speed" ofVelocity Control Mode.• This input is invalid.Position/Full-closedcontrolVelocity controlTorque controlPr4E01[Default]2ContentClears the counter of positional devia-tion and full-closed deviation while CL isconnected to COM–.Clears the counter of positional deviationand full-closed deviation only once byconnecting CL to COM– from open status.CL is invalidAlarm clear input 31 SIP.193A-CLR • You can release the alarm status by connecting this to COM– for morethan 120ms.• The deviation counter will be cleared at alarm clear.• There are some alarms which cannot be released with this input.For details, refer to P.252, "Protective Function " of When in Trouble.