97UF-9000JUN 2004Ver. 2.0DP-180/1904.2.5.4. Binary Signal (V.34)This Service Mode is used to check the binary signal output. Signals can be output to the line using thefollowing procedure. (V.34)Press the “V”, ”/\” arrow keys to select the "4: MODEM Test" on the display.↓Press the “SET” key to select the "4: V34 MODEM".↓Press the “SET” key.↓Press the desired number and press the "START" key.↓Press the “STOP” key twice to exit the service mode.Binary Signal TableNumber Signals Number Signals Number Signals01 V34 2400 sr 2400 bps 22 V34 3000 sr 9600 bps 43 V34 3429 sr 4800 bps02 V34 2400 sr 4800 bps 23 V34 3000 sr 12000 bps 44 V34 3429 sr 7200 bps03 V34 2400 sr 7200 bps 24 V34 3000 sr 14400 bps 45 V34 3429 sr 9600 bps04 V34 2400 sr 9600 bps 25 V34 3000 sr 16800 bps 46 V34 3429 sr 12000 bps05 V34 2400 sr 12000 bps 26 V34 3000 sr 19200 bps 47 V34 3000 sr 19200 bps06 V34 2400 sr 14400 bps 27 V34 3000 sr 21600 bps 48 V34 3429 sr 16800 bps07 V34 2400 sr 16800 bps 28 V34 3000 sr 24000 bps 49 V34 3429 sr 19200 bps08 V34 2400 sr 19200 bps 29 V34 3000 sr 26400 bps 50 V34 3429 sr 21600 bps09 V34 2400 sr 21600 bps 30 V34 3000 sr 28800 bps 51 V34 3429 sr 24000 bps10 V34 2800 sr 4800 bps 31 V34 3200 sr 4800 bps 52 V34 3429 sr 26400 bps11 V34 2800 sr 7200 bps 32 V34 3200 sr 7200 bps 53 V34 3429 sr 28800 bps12 V34 2800 sr 9600 bps 33 V34 3200 sr 9600 bps 54 V34 3429 sr 31200 bps13 V34 2800 sr 12000 bps 34 V34 3200 sr 12000 bps 55 V34 3429 sr 33600 bps14 V34 2800 sr 14400 bps 35 V34 3200 sr 14400 bps 56 ANSam15 V34 2800 sr 16800 bps 36 V34 3200 sr 16800 bps 57 CM16 V34 2800 sr 19200 bps 37 V34 3200 sr 19200 bps 58 JM17 V34 2800 sr 21600 bps 38 V34 3200 sr 21600 bps 59 INFO0c & TONEB18 V34 2800 sr 24000 bps 39 V34 3200 sr 24000 bps 60 INFO0c & TONEA19 V34 2800 sr 26400 bps 40 V34 3200 sr 26400 bps 61 PPh & AC & ALT20 V34 3000 sr 4800 bps 41 V34 3200 sr 28800 bps21 V34 3000 sr 7200 bps 42 V34 3200 sr 31200 bps