81UF-9000JUN 2004Ver. 2.0DP-180/190044 Redial Count 0 = no redial~15 = 15 times0 ~ 9 (For Australia Only)Selects the redial count from 0 to 15 times in 1 stepintervals.Note:In order to comply with the requirements TBR21in the EC countries, do not select 15 times.045 Ring DetectCount1 = 1 ring~9 = 9 ringsSelects the ring detection count from 1 to 9 rings in1 ring step intervals.046 On-Hook Time 0 = 0 sec.~90 = 90 sec.Selects the on-hook time between sequentialcommunication calls in 1 second step intervals.047 Response WaitInterval1 = 1 sec.~90 = 90 sec.20 ~ 150 sec.(For France Only)Selects the waiting interval for the response aftercompleting the dialing.048~049Not Used050 Ring Detect Mode 1 = Normal2 = RoughSelects the quality of ringer detection. Use if the linesignal is out of regulation, set to "Rough" so that theunit may detect the ringing signals.051 Not Used052 Pulse Rate 1 = 10 pps2 = 20 ppsSelects the dial pulse rate 10/20 pps.053~054Not Used055 Busy Tone Check 1 = Off2 = OnSelects whether to detect the Busy Tone.056 Dial Tone Check(Specifieddestinations only)1 = Off2 = OnSelects whether to detect Dial Tone before dialingthe telephone number.057 DC Loop Check(Specifieddestinations only)1 = Off2 = OnSelects whether the unit checks the DC Loop duringcommunication.058 Comm. JRNL +Image1 = Off (without image)2 = On (with image)Selects whether the machine prints the COMM.Journal with image.059 Confidential RCVReport1 = Off (does not print out)2 = On (prints out)Selects whether the machine prints the ConfidentialRCV Report.060 Version Indicates the Host softwareversion.061 TX/RX/PRT/CPY TX:****** PRT:******RX:****** CPY:******Displays the transmitted, received, total printed andcopied document count.062 Print Counter 1 = Off2 = OnSelects whether to print in the Fax Parameter List,the counter information that is displayed in theFunction Parameter No. 61.063~067Not UsedFunction Parameter TableNo. Parameter Selections Function