ADJUSTMENT PROCEDUREItem/Preparation Adjustments+B SET-UP1. Receive a Greyscale signal.2. Set the controls:-Brightness: MinimumContrast: MinimumVolume: Minimum1. Confirm the following voltages.B2 148 ± 2VB9 5 ± 0,25V B10 5 ± 0,25VB5 12 ± 0,5V B11 33 ± 1,5VB4 15 ± 1V B7 8 ± 0,5VB12 26 ± 2V B8 6 ± 1VB3 36 ± 1,5V B13 15 ± 1VB1 205 ± 10V B14 -15 ± 1VCut-Off / Ug2 Test1. Receive a Greyscale signal.2. Degauss the tube externally.3. Set the TV into Service Mode 1.4. Select Cutoff mode.To adjust Cutoff connect an oscilloscope to the Bluecathode.Press "STR" and adjust "cutoff" value using the"Yellow" and "Blue" buttons until the black level is160V ± 5V, press "STR" to store the value.Remove the oscilloscope.Select Ug2 adjustment and adjust the screen VR until thedisplay shows "O.K."ABGLEICH Vorbereitungen Abgleich+B - Abgleich1. Testbild empfangen.Helligkeit auf: MinimumKontrast auf: MinimumLautstärke: Minimum1. Folgende Spannungen sind zu überprüfen.B2 148 ± 2VB9 5 ± 0,25V B10 5 ± 0,25VB5 12 ± 0,5V B11 33 ± 1,5VB4 15 ± 1V B7 8 ± 0,5VB12 26 ± 2V B8 6 ± 1VB3 36 ± 1,5V B13 15 ± 1VB1 205 ± 10V B14 -15 ± 1VCut-Off / Ug2 Test1. Testbild empfangen.2. Bildröhre entmagnetisieren.3. Service-Mode 1 anwählen.4. Im Service-Mode den Abgleichpunkt Cutoff DC-Modewählen.Einen Oszillographen an die blaue Katode der Bildröhreanschliessen. STR-Taste drücken und Mit der gelbenund blauen Taste den CUT-OFF Wert auf 160V ± 5Vabgleichen und mit der STR-Taste abspeichern. DenOszillograph entfernen und den Ug2 Test aufrufen. DenAbgleichwert solange ändern, bis OK auf dem Bildschirmerscheint. Den Wert abspeichern.7