60Using Network FunctionPJLink™ ProtocolThe network function of the unit conforms with PJLink™ class 1 and you can operate the following actions from yourcomputer using PJLink™ protocol.• Display setup• Display status querySupported commandsCommands to control the unit with PJLink™ protocol are shown in the table below.PJLink™ security authenticationSet “Panasonic” for the PJLink™ password.• PJLink™ is a pending trademark in Japan, the United States, and other countries or areas.Command Control RemarkPOWR Power control Parameter0 = Standby 1 = Power “On”POWR? Power status query Parameter0 = Standby 1 = Power “On”INPT Input switch ParameterFirst byte: 1 (RGB) fixedSecond byte: Input position (from 1)INPT? Input switch queryAVMT Shutter control Parameter10 = Picture On (picture mute deactivated), 11 = Picture Off (picture on mute)20 = Audio On (audio mute deactivated), 21 = Audio Off (audio on mute)30 = Shutter mode Off (picture and audio mute deactivated)31 = Shutter mode On (picture and audio on mute)AVMT? Shutter control query Parameter11 = Picture Off (picture on mute)21 = Audio Off (audio on mute)30 = Shutter mode Off (picture and audio mute deactivated)31 = Shutter mode On (picture and audio on mute)ERST? Error status query ParameterFirst byte: Means fan error. 0 or 2.Second byte: 0Third byte: 0Fourth byte: 0Fifth byte: 0Sixth byte: Means other error. 0 or 2.Meaning of the 0 – 2 settings:0 = Error is not detected, 2 = ErrorLAMP? Lamp status query Not supportedINST? Input switch list query Parameter11: Computer input12 - 16: Slot 1 input (INPUT1A)Slot 1 input (INPUT1B)Slot 2 input (INPUT2A)Slot 2 input (INPUT2B)Slot 3 input (INPUT3)Numbers greater than 12 are depending on the slot installation conditionNAME? Projector name query Returns empty character (no name information)INF1? Manufacturer name query Returns “Panasonic”INF2? Model name query Returns “TH-85PF12” (for 85-inch model)INFO? Other information query Returns version numberCLSS? Class information query Returns “1”