4-56 System Programming4.2 System ProgrammingToll Restriction — Exception Codes306Description This allows the user to assign numbers which are exceptions to tollrestriction specified in programs [302] – [305].Selection • Code number: 01 – 80• Exception number: 11 digitsDefault All codes – Not storedProgramming 1. Enter 306.Display example: Excepted Table2. Press NEXT.Display: CODE NO?→3. Enter a code number.Pressing NEXT also can enter code number 01.Display example: 01: ...........4. Enter an exception number.To delete the current entry, press CLEAR.To change the current entry, press CLEAR and enter the newnumber.5. Press STORE.6. To program another code, press NEXT or PREV, orSELECT and enter the desired code number.7. Repeat steps 4 through 6.8. Press END.Conditions • There is a maximum of eighty numbers. Each number must have elevendigits, consisting of 0 – 9, , # and x (PAUSE button). The character“x” can be used as a wild card character and is entered by pressing thePAUSE button.• Code numbers 01 – 80 apply to COS number 2, 01 – 60 apply to COSnumber 3, 01 – 40 apply to COS number 4, and 01 – 20 apply to COSnumber 5.Feature Reference Section 3, FeaturesToll Restriction