Installation Guide for Comfort Pack (CPG) Units11High Voltage Power SupplyLIVE ELECTRICAL COMPONENTS!During installation, testing, servicing andtroubleshooting of this product, it maybe necessary to work with live electricalcomponents. Failure to follow all electricalsafety precautions when exposed to liveelectrical components could result in death orserious injury.! WARNINGThe high voltage power supply must agree with the equipmentnameplate.ORMake certain that the volts, hertz, and phase correspond to thatspecified on the unit rating plate, and that the service providedby the utility is sufficient to handle the additional load imposedby this equipment.Power wiring must comply with national, state, and local codes.Follow instructions on unit wiring diagram located on the insideof the access door, or cabinet and in the wiring diagrams includedwith the unit.ONOFFElectrical - Low VoltageLow Voltage Maximum Wire LengthTable defines the maximum total length of low voltage wiringfrom the outdoor unit, to the indoor unit and to the thermostat.24 VOLTSWIRE SIZE MAX. WIRELENGTH18 AWG 150 Ft.16 AWG 225 Ft.14 AWG 300 Ft.Install a separate disconnectswitch at the location of thethrough the wall unit.Thru-the-WallComfort Pack (CPG) Unit