Chapter 7.0 Trouble Conditions7.0 Trouble ConditionsOccasionally, you may have a problem with your Alarm Controller or telephone line. If this hap-pens, your Alarm Controller identifies the problem and displays an error message. Refer to theprovided list when you see an error message on the display. If additional help is required, contactyour distributor for service.Note: This equipment contains no user-serviceable parts, except for the keypad batteries. Disposeof used batteries as per local rules and regulations.When the system detects a trouble condition the following occurs:l The Trouble indicator turns on.l The keypad beeps once every 10 seconds.l Press the [*] key to silence the keypad beeps.Press [*][2] to examine troubles. When viewing troubles, the trouble indicator flashes to identifythe level of trouble being viewed. One flash = level 1, two flashes = level 2 etc.Arming of your system may be impeded by a trouble. To override this condition, enter [*2], scrollto Acknowledge All Troubles and press [*] or enter 999.TroubleConditionTrouble#Level 1Description TroubleTypesTrouble#Level 2TroubleNotificationLevel 3Note: Trouble #s are used to identify the number to view the trouble and depending on the keypadtype being used, identifies which LED or digit illuminates to display the trouble. Similarly,Trouble Notification identifies the range that may be displayed on the keypad. When exploring thetrouble levels, the Trouble indicator will flash to identify which level you are currently viewing.ServiceRequired01 Assorted Trouble types.Time and Date troubles canbe resolved by resetting theTime/Date. To set Time/Datepress [*][6][0][1]. For allother troubles call for ser-vice.Bell Circuit 01RF Jam 02AuxiliarySupply03Loss of clock 04Output 1Fault05- 17 -