LIBRA LIB-P432EX Series Programming Instructions NAPCO Security SystemsPage 28SYSTEM OPT ION S (ADDRES S 1420-1424) 1. Select the desired option by circling the data values foreach digit (left and right). 2. Add the data values (ex: F=15=(1+2+4+8) from the selectedoptions. See page 23). 3. Enter in address location (left and right digits). NOTE: Darkshaded data value box shows option not available. 4. Press u to save.[Default = blank (•) blank (•)][Default = blank (•) blank (•)][Default = blank (•) blank (•)]LEFT DIGIT (SUMOF DATA VALUES)RIGHT DIGIT (SUMOF DATA VALUES)ADDRESS 1420LEFT DIGIT (SUMOF DATA VALUES)RIGHT DIGIT (SUMOF DATA VALUES)ADDRESS 1421LEFT DIGIT (SUMOF DATA VALUES)RIGHT DIGIT (SUMOF DATA VALUES)ADDRESS 1422[Default = (4) blank (•)]LEFT DIGIT (SUMOF DATA VALUES)RIGHT DIGIT (SUMOF DATA VALUES)ADDRESS 1424[Default = blank (•) blank (•)]LEFT DIGIT (SUMOF DATA VALUES)RIGHT DIGIT (SUMOF DATA VALUES)ADDRESS 1423RIGHT DATAVALUES(CIRCLE )SYSTEM OPTIONS1 Interior Normally By-passed2 Enable Global AmbushCode ***4 Reset Day Zone with Arm/Disarm Only8 Enable Residential FireRIGHT DATAVALUES(CIRCLE )SYSTEM OPTIONS1 Auto Bell Teston Arming2 Auto Reset after BurglaryOutput Timeout4 Suppress BypassReminder when Armed8 Enable Local Alarm onFirst Zone AND TripRIGHT DATAVALUES(CIRCLE )SYSTEM OPTIONS1 Opening Report Only afterAlarm Report2 Closing Report Only onConditional Close4 Incl. Sel./Grp. Bypass inCond. Close /Status8 Status ReportRIGHT DATAVALUES(CIRCLE )SYSTEM OPTIONS1 Enable Zone Doubling(Zones 9-12)2 Wireless TroubleActivates Telco 14 Wireless TroubleActivates Telco 38 Enable Alarm Output on TelcoFail only when ArmedRIGHT DATAVALUES(CIRCLE )SYSTEM OPTIONS1 Automatic Interior Bypass/Easy ExitRESERVEDRESERVED8 Resound on WirelessSmoke Low BatterySYSTEM OPTIONSLEFT DATAVALUES(CIRCLE )Disable Keypad FunctionMode Download 1Disable CallbackDownload 2Chirp Output on KeyfobArm/Disarm 4Change Pulse Output toTemporal Output§ 8SYSTEM OPTIONSLEFT DATAVALUES(CIRCLE )Access Control onPGM2 Output 1Maintained KeyswitchArming 2Enable Manager's Mode 4Disable Keypad InstantMode 8SYSTEM OPTIONSLEFT DATAVALUES(CIRCLE )RESERVEDEnable AutoArm if notclosed at end of Window 2Enable Keypad Time/Date Display 4Disable Zone FaultScrolling 8SYSTEM OPTIONSLEFT DATAVALUES(CIRCLE )Don't Clear PGM2 Outputwith Disarm 1Disable 2nd Call Ans.Machine Override 2Enable Loop Supervision 4Disable Code Requiredfor Bypass (Enable EZ Bypass) 8SYSTEM OPTIONSLEFT DATAVALUES(CIRCLE )Line-Fault Test onlywhen Armed** 1Enable Line-Fault Test** 2Inhibit System TroubleAudible at Keypad 4Select Alarm Output forKeyfob Chirp 8For Address 1423: Default depends on EasyMenu Question “EZ ZONE DOUBLING? Y/N”.If yes, then [Default = •(blank) 1].If no, then [Default = •(blank) •(blank)].*NOTE: Address 1423: Default depends on Easy Menu Question :"EZZONE DOUBLING? Y/N". If yes, then [Default = 1]. If no, then [Default =blank (•)].**NOTE: To select "Line-Fault Test only when Armed", you must alsoselect "Enable Line-Fault Test" at address 1423.***NOTE: If "Enable Global Ambush Code" in Address 1422 is selected, thenprogram the 2-digit "Global Ambush Code" in Address 2045. If Address2045 is left blank (•), then, the 2-digit "Global Ambush Code" will be "99".§This feature must be programmed in Fire Alarm applications.