Mitsubishi Electric FX3G-14M series Hardware Manual
Also see for FX3G SERIES: User manualUser manualProgramming manualBeginners manualInstallation manual
FX 3G SERIES PROGRAMMABLECONTROLLERSHARDWARE MANUALThis manual describes the part names, dimensions, mounting,cabling and specifications for the product. This manual is extractedfrom FX 3G Series User's Manual - Hardware Edition. Refer to FX3GSeries User's Manual - Hardware Edition for more details. Beforeuse, read this manual and manuals of relevant products fully toacquire proficiency in the handling and operating the product. Makesure to learn all the product information, safety information, andprecautions.And, store this manual in a safe place so that you can take it out andread it whenever necessary. Always forward it to the end user.RegistrationPhillips is a registered trademark of Phillips Screw Company.The company name and the product name to be described in thismanual are the registered trademarks or trademarks of eachcompany.Effective December 2017Specifications are subject to change without notice.© 2011 Mitsubishi Electric CorporationSafety Precaution (Read these precautions before use.)If the equipment is used in a manner not specified by themanufacturer, the protection provided by the equipment may beimpaired.This manual classifies the safety precautions into two categories:and .Depending on the circumstances, procedures indicated bymay also cause severe injury.It is important to follow all precautions for personal safety.Manual Number JY997D46001Revision FDate December 2017Indicates that incorrect handling may causehazardous conditions, resulting in death orsevere injury.Indicates that incorrect handling may causehazardous conditions, resulting in medium orslight personal injury or physical damage.STARTUP ANDMAINTENANCEPRECAUTIONS• Do not touch any terminal while the PLC's power is on.Doing so may cause electric shock or malfunctions.• Before cleaning or retightening terminals externally cut off allphases of the power supply.Failure to do so may cause electric shock.• Use the battery for memory backup correctly in FX3G SeriesUser's Manual - Hardware Edition.- Use the battery only for the specified purpose.- Connect the battery correctly.- Do not charge, disassemble, heat, put in fire, short-circuit,connect reversely, weld, swallow or burn the battery, or applyexcessive forces (vibration, impact, drop, etc.) to the battery.- Do not store or use the battery at high temperatures orexpose to direct sunlight.- Do not expose to water, bring near fire or touch liquidleakage or other contents directly.- Incorrect handling of the battery may cause heat excessivegeneration, bursting, ignition, liquid leakage or deformation,and lead to injury, fire or failures and malfunctions of facilitiesand other equipment.- When replacing the battery, make sure to use our specifiedproduct (FX 3U-32BL).- When a battery error occurs ("ALM" LED is lit in red), followthe description in FX 3G Series User's Manual - HardwareEdition.• Before modifying or disrupting the program in operation orrunning the PLC, carefully read through this manual and theassociated manuals and ensure the safety of the operation.An operation error may damage the machinery or cause accidents.STARTUP ANDMAINTENANCEPRECAUTIONS• Turn off the power to the PLC before attaching or detaching thememory cassette. If the memory cassette is attached ordetached while the PLC's power is on, the data in the memorymay be destroyed, or the memory cassette may be damaged.• Do not disassemble or modify the PLC.Doing so may cause fire, equipment failures, or malfunctions.For repair, contact your local Mitsubishi Electric representative.• Turn off the power to the PLC before connecting or disconnectingany extension cable.Failure to do so may cause equipment failures or malfunctions.• Turn off the power to the PLC before attaching or detaching thefollowing devices.Failure to do so may cause equipment failures or malfunctions.- Peripheral devices, Display module, expansion boards, andspecial adapters- Connector conversion adapter, extension blocks, and FXSeries terminal blocks- Battery and memory cassette• Do not use the chemicals for cleaning.• If there is the possibility of touching the PLC inside a controlpanel in maintenance, make sure to discharge to avoid theinfluence of static electricity.DISPOSALPRECAUTIONS• Please contact a certified electronic waste disposal companyfor the environmentally safe recycling and disposal of yourdevice. When disposing of batteries, separate them from otherwaste according to local regulations.(For details of the Battery Directive in EU countries, refer toFX3G Series User's Manual - Hardware Edition.)Associated manualsAssociated manualsFX 3G Series PLC (main unit) comes with this document (hardwaremanual).For a detailed explanation of the FX3G Series hardware andinformation on instructions for PLC programming and specialextension unit/block, refer to the relevant documents.Certification of UL, cUL standardsPlease consult with Mitsubishi Electric for information on UL, cULstandard practices and the corresponding types of equipment.Compliance with EC directive(CE Marking )This product complies with EC directive, however, this documentdoes not guarantee that a mechanical system including this productwill comply with EC directive.Compliance to EMC directive and LVD directive of the entiremechanical system should be checked by the user / manufacturer.For more details please contact the local Mitsubishi Electric salessite.Caution for compliance with EC Directive• Please use the FX 3G Series programmable controllers whileinstalled in conductive shielded control panels under a generalindustrial environment.• Programmable controllers are open-type devices that must beinstalled and used within conductive control panels. Pleasesecure the control box lid to the control box (for conduction).Installation within a control box greatly affects the safety of thesystem and aids in shielding noise from the programmablecontroller.• For the control panel, use the product having sufficient strength,fire protectiveness and shielding property to an installationenvironment.• 24 V DC of the power supply must be supplied from the circuitdouble/reinforced insulated from the main power supply (MAINS).Caution for compliance with the LVD directive (EN61010-2-201:2013)(* 1)• To an external connection port other than AC power supplyterminal and AC input/output terminal, connect the circuitseparated from a dangerous voltage by a double/reinforcedinsulation.• Between the commons having the adjacent relay outputterminals, if an external power supply is higher than 120 V AC,the insulation is basic. Therefore, when using 120 V AC or higherexternal power supply and 30 V DC/AC or lower external powersupply between the adjacent commons, do not handle 30 V DC/AC or lower external power supply as a touchable part, (Whenhandling 30 V DC/AC or lower external power supply as atouchable part, add a basic insulation.)TRANSPORTATIONAND STORAGEPRECAUTIONS• When transporting the FX3G Series PLC incorporating theoptional battery, turn on the PLC before shipment, confirm thatthe battery mode is set using a parameter and the ALM LED isOFF, and check the battery life.If the PLC is transported with the ALM LED on or the batteryexhausted, the battery-backed data may be unstable duringtransportation.• The PLC is a precision instrument. During transportation, avoidimpacts larger than those specified in Section 2.1 by usingdedicated packaging boxes and shock-absorbing palettes.Failure to do so may cause failures in the PLC.After transportation, verify operation of the PLC and check fordamage of the mounting part, etc.• When transporting lithium batteries, follow requiredtransportation regulations.(For details of the regulated products, refer to FX3G SeriesUser's Manual - Hardware Edition.)How to obtain manualsFor the necessary product manuals or documents,consult with your local Mitsubishi Electric representative.Manual name Manual No. DescriptionFX 3G SeriesUser's Manual- Hardware EditionJY997D31301MODEL CODE:09R521Explains FX3G SeriesPLC specification detailsfor I/O, wiring,installation, andmaintenance.FX 3S /FX3G /FX3GC/FX 3U/FX 3UC SeriesProgramming Manual- Basic & AppliedInstruction EditionJY997D16601MODEL CODE:09R517Describes PLCprogramming for basic/applied instructions STL/SFC programming anddevices.MELSEC-Q/L/FStructuredProgrammingManual(Fundamentals)SH-080782MODEL CODE:13JW06Programming methods,specifications, functions,etc. required to createstructured programs.FXCPU StructuredProgrammingManual[Device & Common]JY997D26001MODEL CODE:09R925Devices, parameters,etc.provided in structuredprojects of GX Works2.FXCPU StructuredProgrammingManual[Basic & AppliedInstruction]JY997D34701MODEL CODE:09R926Sequence instructionsprovided in structuredprojects of GX Works2.FXCPU StructuredProgrammingManual[ApplicationFunctions]JY997D34801MODEL CODE:09R927Application functionsprovided in structuredprojects of GX Works2.FX SeriesUser’s Manual- DataCommunicationEditionJY997D16901MODEL CODE:09R715Explains N:N link,parallel link, computerlink, no protocolcommunication by RSinstructions/FX 2N -232IF.FX 3S/FX 3G /FX 3GC /FX 3U/FX 3UC SeriesUser's Manual- Analog ControlEditionJY997D16701MODEL CODE:09R619Describes specificationsfor analog control andprogramming methodsfor FX 3S/FX 3G /FX 3GC /FX 3U/FX3UC SeriesPLC.FX 3S/FX 3G /FX 3GC /FX 3U/FX 3UC SeriesUser's Manual- Positioning ControlEditionJY997D16801MODEL CODE:09R620Explains thespecifications forpositioning control ofFX 3S/FX3G /FX3GC /FX 3U/FX3UC Series andprogramming proceduresManual name Manual No. DescriptionSideBSideASideB JAPANESE ENGLISHJY997D46001F |
Related manuals for Mitsubishi Electric FX3G SERIES
Mitsubishi Electric FX3GE-24M series Hardware Manual
Mitsubishi Electric FX3S-10M series Hardware Manual
Mitsubishi Electric FX3U-128M series Hardware Manual
Mitsubishi Electric MELSEC-F FX1N Series Hardware Manual
Mitsubishi Electric Melsec-F FX2NC Series Hardware Manual
Mitsubishi Electric FX2N-16 Hardware Manual
Mitsubishi Electric MELSEC iQ-F FX5-20PG Series Hardware Manual
Mitsubishi Electric FX3S Series User Manual
Mitsubishi Electric FX3UC-16MT/DSS Hardware Manual
Mitsubishi Electric FX3S-30MT/ES-2AD Hardware Manual
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved