Part Number 000007661 11/16 151CONTROL BOARD ERRORSThe control board monitors the following:Low waterGear motor amperageHigh pressureClogged drainThere are two different errors - Soft errors and hard errors.• Soft errors can be reset by cycling power on/off.• Hard errors can not be cleared by cycling power on/off and must be reset by pressing the control boardreset button.LO WATER - WATER LEVEL IS BELOW LOW WATERSENSOR FOR MORE THAN 120 SECONDSSoft ErrorThe control board stops the ice machine, energizes theLo Water & Service lights and leaves the water solenoidenergized. When water contacts the low water probe theice machine will resume ice making.Hard ErrorThe water level sensor has 4 probes and the 2 longestprobes reach to the bottom of the water reservoir. Whenno water is sensed on these probes within 60 secondsof power up (or the water level sensor is disconnectedor shorted) the control board stops the ice machine andenergizes the Lo Water light. The ice machine must bereset by pressing the control board reset button.HI AMPS - GEAR MOTOR AMPERAGE EXCEEDS 3.8 AMPSSoft ErrorThe control board stops the ice machine, energizes the HiAmps & Service lights and initiates a time delay period.The ice machine will restart after the 60 minute delay. Theice machine continues to run if amperage remains below3.8 amps for six hours.