Diagnostic Error Code FRU/Action175-195-XXXThermal Sensor(s) Test aborted by userInformation onlyRe-start the test, if necessary175-196-XXXThermal Sensor(s) test halt, error thresholdexceeded1. Press F3 to review the log file2. Re-start the test to reset the log file175-197-XXXThermal Sensor(s) test warning 1. Make sure the component that is calledout is connected and/or enabled. SeeChapter 6, “Using the Setup Utility,” onpage 492. Re-run test3. Replace the component that is called outin warning statement4. Replace the component under test175-198-XXXThermal Sensor(s) test aborted 1. If a component is called out, make sureit is connected and/or enabled2. Flash the system and re-test. See“Updating (flashing) the BIOS from adisc” on page 3803. Go to “Undetermined problems” on page80175-199-XXXThermal Sensor(s) test failed, causeunknown1. See “Undetermined problems” on page802. Flash the system and re-test. See“Updating (flashing) the BIOS from adisc” on page 3803. Replace component under function test175-250-XXX175-251-XXXThermal Sensor(s) limit error1. Check fans2. Check Power supply voltages3. Microprocessor4. System board185-000-XXXAsset Security Test PassedNo action185-XXX-XXXAsset Security failure 1. Flash system2. System board185-278-XXXAsset Security Chassis Intrusion 1. Assure Asset Security Enabled2. C2 Cover Switch3. System board201-000-XXXSystem Memory Test PassedNo action201-XXX-XXXSystem Memory error 1. Replace the memory module called outby the test2. System board202-000-XXXSystem Cache Test PassedNo action202-XXX-XXXSystem Cache error 1. Cache, if removable2. System board3. MicroprocessorChapter 7. Symptom-to-FRU index 73