Diagnostic Error Code FRU/Action030-198-XXXSCSI interface test aborted 1. If a component is called out, make sureit is connected and/or enabled. SeeChapter 6, “Using the Setup Utility,” onpage 492. Flash the system and re-test. See“Updating (flashing) the BIOS from adisc” on page 3803. Go to “Undetermined problems” on page80030-199-XXXSCSI interface test failed, cause unknown 1. Go to “Undetermined problems” on page802. Flash the system and re-test. See“Updating (flashing) the BIOS from adisc” on page 3803. Replace component under function test035-000-XXXRAID interface Test PassedNo action035-0XX-XXXRAID interface Failure 1. RAID signal cable2. RAID device3. RAID adapter card, if installed4. System board035-195-XXXRAID interface Test aborted by userInformation onlyRe-start the test, if necessary035-196-XXXRAID interface test halt, error thresholdexceeded1. Press F3 to review the log file2. Re-start the test to reset the log file035-197-XXXRAID interface test warning 1. Make sure the component that is calledout is connected and/or enabled. SeeChapter 6, “Using the Setup Utility,” onpage 492. Re-run test3. Replace the component that is called outin warning statement4. Replace the component under test035-198-XXXRAID interface test aborted 1. If a component is called out, make sureit is connected and/or enabled. SeeChapter 6, “Using the Setup Utility,” onpage 492. Flash the system and re-test. See“Updating (flashing) the BIOS from adisc” on page 3803. Go to “Undetermined problems” on page80035-199-XXXRAID interface test failed, cause unknown 1. See “Undetermined problems” on page802. Flash the system and re-test. See“Updating (flashing) the BIOS from adisc” on page 3803. Replace component under function test68 Hardware Maintenance Manual